6-80
Ink drops hit each other.
6.5.24 Ink deposition on Printhead cover
A
s the ink is ejected onto the print target, during IJP operation, the printhead cover
(inside/outside) will be stained by the ink splashes back from the print target.
To prevent IJP from printing malfunction caused by the ink staining on Printhead,
check the condition of the printhead cover periodically and clean it as necessary.
The figures below show the mechanism of how the ink splashes are generated and stain the
printhead, and then ink deposition is generated.
Image of ink stain
Ink drops on print
target get dried.
Print
target
When the ink drop hits the one in front of
before it gets dried, many ink splashes
will be generated.
Printing Conditions(right figure)
*Ink drops are making contacts in small
character height.
*Print speed is fast.
Printing Conditions(left figure)
*Ink drops are placed separately in large
character height.
*Print speed is slow.
Ink drops which reached print target generate
the ink splashes but a small amount. Ink
drops get dried soon when the printing speed
is slow.
Print
target
Ink splashes are
negatively-charged
because these are
generated from
negatively-charged ink
drops.
Negatively-charged ink splashes are attracted
by positively-charged deflection electrode and
then ink deposition is generated, which is
formed like a whisker.
Image of ink stain
Print
target
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...