2-5
2.3 Adjustment/operational checkout
2.3.1 Excitation adjustment
●
Adjust the drive conditions of nozzles.
●
This adjustment is performed in a state other than the IJ printer “ready” state.
●
Be sure to perform this adjustment in the case of replacing the board (EZJ126, 125, 128), or the
nozzle (including the print head) or changing the ink type.
In addition, when this adjustment is performed, be sure to carry out “2.3.4 Auto phase gain
adjustment.”
1 Press Adjustment/operational checkout on the maintenance menu.
If Adjustment/operational checkout is not displayed on the maintenance menu, set the service
personnel maintenance mode on the login user selection screen.
The adjustment/operational checkout menu is then displayed.
2 Press Excitation adjustment.
The excitation adjustment screen is then displayed.
For information on changing to the service personnel maintenance mode,
refer to “2.1 Setting of service personnel maintenance mode.”
Excitation adjustment
Manua
l
Start
up
HOME
Back
Adjust./oper. checkout
Excitation
adjustment
Charge voltage
confirmation
Phase margin test
Heating unit
confirmation
Auto-phase gain
adjustment
Level sensor
confirmation
[Stop ]
2015.07.07 12:45
Com=
0
Back
Adjust./oper. checkout
<Excitation adjustment>
0752
Excitation voltage value
(0-2047)
Automatic
adjustment
Proc. status:
[Stop ]
2015.07.07 12:45
Com=0
Automatic adjustment
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...