2-53
●
Automatic ink & makeup replenishment sequence
Printing
(30 minutes)
Viscosity
measurement
Waiting for
defoaming
(10 minutes)
Ink
replenishment
(for dot count)
Makeup
replenishment
Ink
replenishment
(to initial level)
<Log timing>
(1) Except Pigment model: End of Step B1
(2) Pigment model: End of Step B2
●
Mode (Result of Automatic ink replenishment)
- Normal end
Mode = 1: Normal end at Step B1 or Step B2.
- The main tank ink level is higher than initial level when increasing or reducing
concentration control.
= 2: Normal end at Step C1.
- The main tank ink level becomes higher than initial level after ink
replenishment for dot count.
= 4: Normal end at Step C2
= 5: Normal end at Step C3
- Abnormal end or terminated
Mode = A: Abnormal end at step B1
= B: Terminated at step B1
= C: Abnormal end at step B2
= D: Terminated at step B2
= E: Abnormal end at step C1
= F: Terminated at step C1
= G: Abnormal end at step C2
= H: Terminated at step C2
= J: Abnormal end at step C3
= K: Terminated at step C3
(1)
(2)
Step B1
Step B2
Step C1
Step C2
Step C3
Step B2 is for Pigment ink only.
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...