2-49
Hitachi IJP - Model UX
Careful Cleaning Instruction Manual
This is the function to clean the nozzle carefully when shutting down IJP.
Please read the instructions below and execute “Careful cleaning” function.
1. Operation
1.1 Operation procedures of “Careful cleaning” shutdown process
(1) Press Shutdown button at top right of the screen and [Shutdown Process Confirmation]
message will appear, as shown in bottom half of the figure below. *1
(2) Press Careful cleaning button.
The regular shutdown process with nozzle cleaning is executed by pressing OK
button or STOP*2 button.
*1 If [Shutdown Process Confirmation] message does not appear, go to Item 1.2 below.
*2 STOP button will only show up with Model UX-D,E.
1.2 Confirmation of setup items for Confirmation message display of Control menu
In case that even the Shutdown button at top right is pressed but [Shutdown Process
Confirmation] message does not appear, go to “Environment setup menu” screen and press
Touch screen setup. Then, press Display of “Confirmation window for Manual Control Menu”.
If Nondisplay is selected, the shutdown process of “Careful cleaning” is NOT available.
(
(
2
2
)
)
(
(
1
1
)
)
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...