6-76
6.5.20 Startup process after long-term shutdown and How to restore
the operation
Yes
When the viscometer is working,
is Red indicator turned OFF?
No
Refer to
“4.12 Troubleshooting when Fault Occurs in Viscometer”
Viscometer verification
Restore
“Recovery line operation check”
This operation is the work for checking for ink clogging.
The operational procedure equals to operating in the sequence of Pump
→
MV3 on “Valve/Pump test”
*1)
Circulation line verification
Yes
Are the valves making
operation sound?
No
Refer to “4.5 solenoid valve replacement” and/or “5.5 Shutoff valve
(MV9) replacement” or “4.15.1 How to restore operation when solenoid
valve seizure occurs”.
Is the ink flow at tube B confirmed at
“Recovery line operation check”? *1)
Yes
Are BOTH “Ink Drainage” AND “Ink Refill”
executed TWO TIMES IN A ROW?
Yes
No
Refer to “4.14
Troubleshooting Procedure for the Circulation System”,
Trouble symptom [No collection], Probable cause [The collection pump
malfunctions].
Is the problem fixed?
No
No
Yes
No
Refer to “4.14 Troubleshooting
Procedure for the Circulation System”, Trouble
symptom [Ink does not jet.] and [Makeup does not
circulate.], and “6.5.8 No ink ejection
from nozzle”.
Refer to “4.14 Troubleshooting Procedure for the
Circulation System”,
Trouble symptom [Ink does not jet.],
Probable cause [The supply pump malfunctions].
No
Restore
Restore
Solenoid valve verification
Recovery line verification
Supply/Cleaning line verification
Yes
Does makeup eject at “Ink stream
alignment”?
[NOTE]
When the makeup does not eject the 1st
time, please try the 2nd time.
Restore
Yes
(*) BOTH “Ink Drainage” AND “Ink Refill” are executed
TWO TIMES IN A ROW.
“Restart Operation After Long-Term Shutdown” is completed.
“Restart Operation After Long-Term Shutdown”
Refer to “4.14 Troubleshooting Procedure for the
Circulation System”,
Trouble symptom [No collection] and
“6.5.18 No ink suction from gutter”.
Restore
Execute <Process after long-term shutdown>.
(*)
Refer to “4.14
Troubleshooting Procedure for the Circulation
System, Trouble symptom [Charging or drainage is impossible.]
and [When the message “Failure was detected in level sensor,
pump, or solenoid valve” is displayed on the screen.].
Does “Ink Beam Bent” occur?
Restore
Refer to “6.5.6 Ink
leakage/blowout“.
Does Ink pressure change by arbitrarily rotating
the handle of Pressure reducing valve?
Yes
No
Restore
Refer to “4.14 Troubleshooting Procedure for the Circulation
System”, Trouble symptom [The ink pressure does not
increase.] and “4.3 Pressure reducing valve replacement”.
Does an alarm like “Ink pressure low” or “No ink
drop charge” occur?
No
Refer to “4.14 Troubleshooting Procedure for the
Circulation System”, Trouble symptom [The ink pressure
does not increase], and
“4.12 Troubleshooting when Fault Occurs in Viscometer”.
Restore
Yes
Is the problem fixed?
Occur
Not occur
Occur
Not occur
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...