2-12
Example of [Print timing: Sensor]
To quit before the process is complete, press Abort.
5 Determination method of test.
View the printing results for phases 0 to 15 (f), and if printing is normal within the range of one
phase before to one phase after the “print phase which is set at present”, there is no problem.
If printing is not normal within the range of one phase before to one phase after the print
phase which is set at present, the nozzle may be clogged or ink quality may have
deteriorated. Clean the nozzle, replace ink, etc.
(Example)
:
5 7
■■ A B C 1 2 3
6 7
■■ A B C 1 2 3
7 7
■■ A B C 1 2 3
8 7
■■ A B C 1 2 3
9 7
■■ A B C 1 2 3
:
[Print contents ]
■
■
A B C 1 2 3
Printed phase
Printed phase which is set at present
(16 phase in total
(
a phase determined to be suitable
)
from 0 to f)
Specify phase.
[Ready ]
Adjust./oper. checkout
<Phase margin test>
Abort
Proc. status: In progress
Print timing
Print data
Print phase
Printing starts upon signal from sensor.
Print phase:
X
-phase (0-f)
Button input
Sensor
For test
Data to be displayed
Automatic update
Specified phase
2015.07.07 12:45
Com=0
Dec.
Inc.
Abort
Range of one phase before to one phase after the
print phase which is set at present
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...