4.14 Troubleshooting Procedure for the Circulation System
Perform “(1) Fault locating and repairing method” for each trouble symptom.
For the items marked * in “Probable Cause”, perform “(2) Fault locating method for the control
system/circulation system” to make sure that the control system is normal, and then perform the repair
work.
(1) Fault locating and repairing method
Trouble
symptom
Probable cause
Status check
Repairing method
Ink does
not eject.
The supply
pump
malfunctions
.
* The motor
malfunctions.
The motor does not
rotate.
Replace the motor.
The drive cam
is damaged.
A crack or powder
abrasion is found on
the cam.
Replace drive unit
The follow
operation of the
stroke is faulty.
The piston cannot
follow the cam
motion.
Replace supply pump
head
Foreign
materials are
mixed in the
check valve.
The solenoid valve is
operated but
charging and
drainage are not
completed within the
specified time.
When the fault is not
recovered by repeating
“startup” and
“shutdown”, replace the
supply pump head.
The check
valve is dry or
sticks.
The solenoid valve is
operating but ink
does not flow.
Refer to “4.15
Repairing method
when the circulation
route is dry or sticks”.
The solenoid
valve
malfunctions
.
* MV1
malfunctions.
When “Open” is
executed on
“Solenoid
Valve/Pump Test”
screen, no operation
sound is produced.
Replace or repair the
solenoid valve (MV1).
Refer to “4.15
Repairing method
when the circulation
route is dry or sticks”.
* MV9
malfunctions.
When “Open” is
executed on
“Solenoid
Valve/Pump Test”
screen, no operation
sound is produced.
Replace the solenoid
valve (MV9).
The supply
route clogs.
Clogging in the
pipe or joint.
The operation sound
of MV1 and MV9 is
produced, but ink
does not flow.
Refer to “4.15
Repairing method
when the circulation
route is dry or sticks”.
Clogging in the
orifice plate.
When backwash
conducted, makeup
does not flow to the
tube of circulation
route.
Clean the orifice plate
with
ultrasonic
cleaning.
Makeup
does not
eject.
The makeup
pump
malfunctions
.
Follow the same descriptions as those of “The supply pump
malfunctions" above.
However, replace the makeup pump
head instead.
The solenoid
valve
malfunctions
.
* MV8
malfunctions.
When “Open” is
executed on
“Solenoid
Valve/Pump Test”
screen, no operation
sound is produced.
Replace the solenoid
valve (MV8).
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...