4-49
(2) Fault locating method for the control system/circulation system
(a) When the pump motor and all the solenoid valves are not operated, the multi-power supply
(24 V system) is abnormal.
(b) If the electrical parts (pump motor, solenoid valves, and pressure sensor) are not operated, i,e.,
any case other than above, make the following checks first. When the criterion is satisfied, the
power supply, EZJ126 board, wiring, or connector is abnormal.
Part
Check method
Criterion
Pump motor
(1) Operate the pump
on the “Solenoid
Valve/Pump Test”
screen.
(2) Measure the
voltage at pin
No.5 (wire: red)
20 V DC or more
Solenoid valve
(1) Exchange the
solenoid valve
and/or the
connector with
another normal
solenoid valve
and/or connector.
(2) Set the solenoid
value to “Open” on
the “Solenoid
Valve/Pump Test”
screen and check
the sound.
An operation sound shall be
produced.
Pressure sensor
Measure the voltage
at pin No.1
(wire: yellow)
DC12V
±
10%
Measure the voltage
at pin No.3 (wire:
blue) when the ink is
jetting.
Pressure
[MPa]
Output
voltage [V]
0.1
1.5 to 1.6
0.2
2.1 to 2.2
0.3
2.7 to 2.8
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...