4-40
4.12.3 Viscometer assembly procedure
1 Replace the cylinder, and then insert the plunger. Handle the plunger with tweezers
making sure that no dust adheres to the surface of plunger.
2 Set the collar to cylinder, paying extra attention to its orientation (with the convex up).
3 Make sure that the O-ring is set in the viscometer cover, and then assemble the cover into
the viscometer case.
4 Attach the three viscometer setscrews and tighten them. (Tighten the screws with
reasonable force using screwdriver. Tightening the screws excessively will break the
threads.)
4.12.4 Viscometer attaching procedure
1 Set the O-ring on the viscometer OUT side, and use the setscrews (2 pieces) to attach the
viscometer to the circulation unit.
2 Plug in the connectors.
3 Connect the viscometer IN-side tube (mark G).
[Caution] After reassembly, it may be necessary to replace the ink and/or calibrate the
viscometer.
When disassembling and washing during installation:
Calibrate the viscometer. Ink replacement is NOT required.
When replacing the viscometer during installation:
Calibrate the viscometer. Ink replacement is NOT required.
When replacing the viscometer in cases other than installation:
First replace the ink, then calibrate the viscometer.
O-ring
Viscometer case
Viscometer IN joint
Viscometer cover
Plunger
Cylinder
Coil
Collar
O-ring
O-ring
Thermistor
Fixing
plate
Viscometer-IN
Viscometer-Out
Содержание IJ UX
Страница 1: ...Service Manual HITACHI Printer Model UX Revision July 1 2015 Version ...
Страница 2: ... Revision of UX service manual Revision Chapter Revised Page Frist Edition ...
Страница 15: ...1 9 2 External views Rear side 1 2 2 Main body internal Appearance with inner cover T removed ...
Страница 16: ...1 10 1 2 3 Print head UX E UX D B Air exhaust port ...
Страница 107: ...3 27 Circuit diagram of EZJ127A ...
Страница 108: ...3 28 Circuit diagram of EZJ127B ...
Страница 122: ...3 42 Circuit diagram of EZJ129 ...
Страница 131: ...3 51 3 3 20 Electrical Connection Diagram ...
Страница 132: ...3 52 ...
Страница 188: ...4 55 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Страница 301: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram UX B D 7 1 ...
Страница 302: ...Circulation System Diagram UX E 7 2 ...
Страница 303: ...7 3 Location of Solenoid valve Location of ICU joint Reducing valve Viscometer Pressure sensor Makeup filter Motor Pump ...
Страница 304: ...7 2 Electrical Connection Diagram 7 2 1 Electrical Connection Diagram UX D E 7 4 Electrical Connection Diagram UX D E ...
Страница 305: ...7 5 7 2 2 Electrical Connection Diagram UX B Basic model Electrical Connection Diagram UX B ...
Страница 308: ... Nozzle diameter 65μm 7 8 7 4 Dimensions around charge electrode and deflection electrode ...