GENERAL DATA
2
/9
2.2.
GENERAL DATA FOR OUTDOORS UNITS
2.2.1.
RAS - OUTDOORS UNIT (FSG/FSG1)
MODEL RAS
RAS-5FSG
RAS-8FSG
RAS-10FSG
RAS-16FSG
RAS-20FSG
RAS-24FSG1
RAS-30FSG1
Power Supply
AC 3
BBBB
, 380-415V, 50Hz
Nominal Cooling Capacity
kW
14.1
22.6
28.3
45.0
56.0
69.0
85.0
Nominal Heating Capacity
kW
16.3
26.1
32.6
50.0
63.0
77.5
95.0
Cabinet
Color (MunsellCode)
Synthetic Resin Paint Baked on Galvanized Steel Plate
Beige (2.5Y 8/2)
Sound Pressure Level
(Overall A Scale)
dB
47
51
53
56
57
63-58
(Nigth
Shift)
64-59
(Nigth
Shift)
Outer Dimensions
Height
mm
1 645
1 645
1 645
1 645
1 645
1 645
1 645
Width
mm
630
950
950
1,910
1,910
2 870
2 870
Depth
mm
750
750
750
750
750
750
750
Net Weight
kg
190
275
280
485
540
790
820
Refrigerant
Flow
Control
R407C
Micro-Computer Control Expansion Valve
Compressor
Hermetic (Scroll)
Model
G402DHV
G
G401DHM
G
G501DHM
G
G601DHM
´
2
G
G601DHM
´
3
G750EH
´
2
G1200EH
´
2
Quantity
1
1+1
1+1
1+1
´
2
1+1
´
3
4
4
Motor Output (Pole)
kW
3.0 (2)
3.0+3.0 (2)
3.0+3.75 (2)
3.0+4.4 (2)
´
2
3.0+4.4 (2)
´
3
3.0(4)x1+4.4
(2)x1+5.5(2)x2
3.0(4)x1+4.4
(2)x1+7.5(2)x2
Oil quantity
l
2.4
4.1
4.1
6.1
8.2
12.9
13.3
Heat Exchanger
Multi-Pass Cross-Finned Tube
Condenser Fan
Propeller Fan
Quantity
1
1
1
2
2
3
3
Air Flow Rate
m³/min
87
138
172
278
344
426
531
Motor Output (Pole)
W
160(6)
275(6)
275(6)
275(6)
275(6)
275(6)x3
275(6)x3
Refrigerant Piping
Flare-Nut and/or Flange Connection (Factory supplied)
Liquid Line
mm
(in.)
Ø9.53
(3/8)
Ø12.7
(1/2)
Ø12.7
(1/2)
Ø15.88
(5/8)
Ø15.88
(5/8)
Ø19.05
(3/4)
22.2
(7/8)
Gas Line
mm
(in.)
Ø19.05
(3/4)
Ø22.2 or
Ø25.4
(7/8 or 1)
Ø25.4 or
Ø28.6
(1 or 1-1/8)
Ø28.6 or
Ø31.75
(1-1/8 or 1-1/4)
Ø34.9 or
Ø38.1
(1-3/8 or 1-1/2)
Ø34.9 or
Ø38.1
(1-3/8 or 1-1/2)
Ø41.3 or
Ø44.45
(1-5/8 or 1-3/4)
Refrigerant Charge
kg
5.4
10.0
11.5
16.0
22.0
25.0
28.5
Wiring Holes
Power Supply
mm
Ø56
Ø56
Ø56
Ø56
Ø56
Ø70
Ø70
Control Circuit
mm
Ø26.5
Ø26.5
Ø26.5
Ø26.5
Ø26.5
Ø26.5
Ø26.5
Connecting Wire between
Indoor and Outdoor Unit
2
2
2
2
2
2
2
Approximate
Packing Measurement
m³
0.93
1.37
1.37
2.85
2.85
4.32
4.32
?
NOTE:
1. The Sound Pressure Level is based on following
conditions:
- 1 meter from the unit front surface and 1.5 meter
from floor level.
The above data was measured in an anechoic
chamber so that reflected sound should be taken
into consideration in the field.
Conditions: as designed in Eurovent procedures for
sound testing.
In case of Night Shift conditions, the noise level
decrease 2 dB (A)
2. The outdoor unit is charged with refrigerant before
shipment. The charged volume is the equivalent of
a refrigerant piping of 10 meters, when combining
to HITACHI standard indoor unit.
Содержание FSG Series
Страница 2: ......
Страница 4: ......
Страница 13: ...3 57 7 1 7 ...
Страница 14: ......
Страница 110: ......
Страница 116: ......
Страница 146: ......
Страница 159: ...CONTROL SYSTEM 9 13 9 6 STANDARD OPERATION SEQUENCE 9 6 1 COOLING OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 160: ...9 14 CONTROL SYSTEM n Cooling Operation FSG FSG1 cont ...
Страница 161: ...CONTROL SYSTEM 9 15 9 6 2 COOLING MAINLY COOLING OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 162: ...9 16 CONTROL SYSTEM n Cooling mainly Cooling Operation FXG FXG1 cont ...
Страница 163: ...CONTROL SYSTEM 9 17 9 6 3 DRY OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 164: ...9 18 CONTROL SYSTEM n Dry Operation FSG FSG1 cont ...
Страница 165: ...CONTROL SYSTEM 9 19 9 6 4 DRY OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 166: ...9 20 CONTROL SYSTEM n Dry Operation FXG FXG1 cont ...
Страница 167: ...CONTROL SYSTEM 9 21 9 6 5 HEATING OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 168: ...9 22 CONTROL SYSTEM n Heating Operation FSG FSG1 cont ...
Страница 169: ...CONTROL SYSTEM 9 23 9 6 6 HEATING MAINLY HEATING OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 170: ...9 24 CONTROL SYSTEM n Heating mainly Heating Operation FXG FXG1 cont ...
Страница 171: ...CONTROL SYSTEM 9 25 n Defrosting Operation Control ...
Страница 172: ...9 26 CONTROL SYSTEM 9 7 STANDARD CONTROL FUNCTIONS 9 7 1 FREEZING PROTECTION CONTROL DURING COOLING OR DRY OPERATION ...
Страница 173: ...CONTROL SYSTEM 9 27 9 7 2 GAS BYPASS CONTROL 9 7 3 OVER HEATING PROTECTION CONTROL ...
Страница 176: ...9 30 CONTROL SYSTEM 9 7 6 CONTROL FOR AUTO COOL HEAT OPERATION ...
Страница 228: ......
Страница 229: ...3 57 167 7 21 7 ...
Страница 230: ......
Страница 287: ...REFRIGERANT PIPING AND REFRIGERANT CHARGE 13 11 GAS LINE LIQUID LINE E 152S E 162M1 E 202M1 E 242S E 302S ...
Страница 324: ......
Страница 344: ......
Страница 376: ......
Страница 423: ......
Страница 424: ...TCGB0023 rev 0 04 04 Printed in Spain ...