![Hitachi FSG Series Скачать руководство пользователя страница 350](http://html.mh-extra.com/html/hitachi/fsg-series/fsg-series_technical-catalogue_139455350.webp)
16
/6
INSTALLATION OF OPTIONAL REMOTE CONTROLLER
Address of Indoor Units:
Main unit
1
st
unit
2
nd
unit
3
rd
unit
8
th
unit
9
th
unit
10
th
unit
11
th
unit
4
th
unit
5
th
unit
6
th
unit
7
th
unit
12
th
unit
13
th
unit
14
th
unit
15
th
unit
16.2
INSTALLATION OF REMOTE CONTROL SWITCH (CORE-FUNCTION) <PC-P5H>
n
Selection of Installation Place
§
Select a suitable place for handling and determine the
installation place of the controller with the customer’s
acceptance.
§
Do not install the controller at such places as:
– Where children can touch
– Where the air from the air conditioner is directly
discharged
n
Before Installation
Check the contents and the number of the accessories in
the packing.
Remote Control
Switch, for
Operation Control
2 screws
Ø4x16L
For fixing the
Holding Bracket
onto the wall
Ring
Core1
Band
For fixing
Cable to
Ring
Core
Cable
(20 cm)
n
Installation Space
§
In case of installing the controllers in vertical line, keep
a distance more than 50mm between the controllers
vertically.
If the distance is insufficient, the front cover of the
controller can not open wide enough.
More than
50 mm
n
Installation Procedures
1. Insert the edge of the screwdriver into the groove parts at
the bottom of the holding bracket, push and turn the
screw driver and remove the controller from the holding
bracket
.
Figure seen from Bottom Side
Groove Part
Screw Driver
2. Connection of cable.
Connect the accessory cable to the fielded cable by
soldering.
Accessory Cable
Field Supplied Cable
(Insulate the connecting part by vinyl tape)
3. Attach the controller to the holding bracket and connect
the cable as follows.
In Case of Exposing Remote Control Cable
Fix the Holding Bracket onto
the wall with screws
(Accessory)
Approx. 6 mm
Содержание FSG Series
Страница 2: ......
Страница 4: ......
Страница 13: ...3 57 7 1 7 ...
Страница 14: ......
Страница 110: ......
Страница 116: ......
Страница 146: ......
Страница 159: ...CONTROL SYSTEM 9 13 9 6 STANDARD OPERATION SEQUENCE 9 6 1 COOLING OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 160: ...9 14 CONTROL SYSTEM n Cooling Operation FSG FSG1 cont ...
Страница 161: ...CONTROL SYSTEM 9 15 9 6 2 COOLING MAINLY COOLING OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 162: ...9 16 CONTROL SYSTEM n Cooling mainly Cooling Operation FXG FXG1 cont ...
Страница 163: ...CONTROL SYSTEM 9 17 9 6 3 DRY OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 164: ...9 18 CONTROL SYSTEM n Dry Operation FSG FSG1 cont ...
Страница 165: ...CONTROL SYSTEM 9 19 9 6 4 DRY OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 166: ...9 20 CONTROL SYSTEM n Dry Operation FXG FXG1 cont ...
Страница 167: ...CONTROL SYSTEM 9 21 9 6 5 HEATING OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Страница 168: ...9 22 CONTROL SYSTEM n Heating Operation FSG FSG1 cont ...
Страница 169: ...CONTROL SYSTEM 9 23 9 6 6 HEATING MAINLY HEATING OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Страница 170: ...9 24 CONTROL SYSTEM n Heating mainly Heating Operation FXG FXG1 cont ...
Страница 171: ...CONTROL SYSTEM 9 25 n Defrosting Operation Control ...
Страница 172: ...9 26 CONTROL SYSTEM 9 7 STANDARD CONTROL FUNCTIONS 9 7 1 FREEZING PROTECTION CONTROL DURING COOLING OR DRY OPERATION ...
Страница 173: ...CONTROL SYSTEM 9 27 9 7 2 GAS BYPASS CONTROL 9 7 3 OVER HEATING PROTECTION CONTROL ...
Страница 176: ...9 30 CONTROL SYSTEM 9 7 6 CONTROL FOR AUTO COOL HEAT OPERATION ...
Страница 228: ......
Страница 229: ...3 57 167 7 21 7 ...
Страница 230: ......
Страница 287: ...REFRIGERANT PIPING AND REFRIGERANT CHARGE 13 11 GAS LINE LIQUID LINE E 152S E 162M1 E 202M1 E 242S E 302S ...
Страница 324: ......
Страница 344: ......
Страница 376: ......
Страница 423: ......
Страница 424: ...TCGB0023 rev 0 04 04 Printed in Spain ...