![Hioki 8730-10 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/hioki/8730-10/8730-10_instruction-manual_2137220095.webp)
79
_____________________________________________________________________________________________
4.4 Trigger Functions
______________________________________________________________________________________________
4.4.4 Trigger Source AND/OR Linking
Setting Screen: Trigger
Trigger Source (OR, AND)
NOTE
Channel
Trigger
Trigger Level
Slope
Filter
CH1
Level
0.000 V
UP
OFF
CH2
Level
0.000 V
UP
OFF
時間
T
トリガレベル
(0V)
CH1
CH2
T
CH1、CH2とも0Vを下から
上に横切っている
時間
T
トリガレベル
(0V)
CH1
CH2
T
T
T
CH1、CH2のどちらか一方が
0Vを下から上に横切っている
T
AND
OR
Trigger Level
Both CH1 and CH2
cross the 0V-line in an
upward direction.
Either CH1 or CH2
crosses the 0V-line in
an upward direction.
Trigger Level
Time
Time
The channel trigger [CH1, CH2
(Note)
], external trigger, and timer trigger
may be combined to activate a trigger using AND/OR logic.
(Note) Only CH1 is available with the 8730-10.
Setting Procedure
1. Press the
DISPLAY
key and use the right
and left
CURSOR
keys to select the
"
Trigger
" tag.
2
.
Select "
Trigger Source
" on the display
menu, then press the
ENTER
key.
3. Select an item, then press the
ENTER
key.
OR : Activates a trigger when any trigger
source meets the set conditions.
AND: Activates a trigger when all trigger
sources meet the set conditions.
If the trigger sources are set to "
AND
", and
the trigger source setting conditions have
already been met when the
START
key is
pressed, triggering does not occur. When the
conditions are not met once but met
subsequently, triggering occurs.
(Setting Example)
When the trigger sources are set as shown below, a trigger is activated
differently depending on the AND/OR setting as shown in the figure below.