Commands
────────────────────────────────────────────────────
■
Reads out the saved data.
Syntax
:MEMory:READ:MEASure?_<
data>
data
Numerical data in NR1 format and character data, <data unit number> and
<measuring mode> in order
<Data unit number>
Numerical value from 1 to the number of models (total
number of data units)
<Measuring mode>
EARTh/ENCLosure/RESistance/PATient1 (PAT1)/
PATient2 (PAT2)/PATient3 (PAT3)/PAUXiliary
(ME equipment)
EARTh Earth leakage current
ENCLosure Enclosure leakage current
RESistance Low resistance measurement
PATient1 Patient leakage current
PATient2 Patient leakage current
PATient3 Patient leakage current
PAUXiliary Patient auxiliary current
(Ordinary equipment)
EARTh Earth leakage current
ENCLosure Enclosure leakage current
RESistance Low resistance measurement
Function
Returns the saved data of the specified measuring mode of the specified
data unit.
The data are orderd as follows, and the available data is read in a format
from
to
(for enclosure leakage current,
to
, and for low resistance
measurement,
to
). If there is no saved data, returns "0" only.
For earth leakage current, patient leakage current
, patient leakage
current
, patient leakage current
and patient auxiliary current
<
maximum value>, <
judgment>, <
power source polarity>, <
condition of the equipment to be measured>, <
measurement network
filter> and <
measurement current>
For enclosure leakage current
<
maximum value>, <
judgment>, <
power source polarity>, <
condition of the equipment to be measured>, <
measurement network
filter>, <
measurement current> and <
contact condition>
For low resistance measurement
<
maximum value> and <
judgment>
:MEMory:READ:MEASure?
Содержание 3155-01
Страница 1: ...LEAK CURRENT HiTESTER INSTRUCTION MANUAL 3155 01...
Страница 2: ......
Страница 12: ......
Страница 27: ...7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 2 Names and Functions of Parts...
Страница 45: ...25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 4 Preparations for Measurement...
Страница 129: ...109 5 11 System Screen ME Equipment Example of a data unit printout Example of a details printout...
Страница 135: ...115 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 6 Ordinary Electrical Equipment Measurement Network C Installed...
Страница 189: ...169 6 7 System Screen for IEC TR 60990 Example of a data unit printout Example of a details printout...
Страница 195: ...175 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 7 Ordinary Electrical Equipment Measurement Network D Installed...
Страница 243: ...223 7 7 System Screen Universal Example of a data unit printout Example of a details printout...
Страница 314: ...294...
Страница 322: ...302 9 3 Accuracy Tables...
Страница 334: ...314 10 6 External Dimensions 292 2 110 2 212 2 115 8 2 10 6 External Dimensions...
Страница 335: ...315 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 APP Appendices...
Страница 362: ...INDEX 6 Index...
Страница 363: ......
Страница 364: ......
Страница 365: ......