29
ADM for analog sensors in slot ADM1
6 wires
4 wires
1
+ Excitation
1 / 3
+ Excitation
2
– Excitation
2 / 4
– Excitation
3
+ Sense
5
+ Signal
4
– Sense
6
– Signal
5
+ Signal
6
– Signal
Connection of an analog SG sensor in 4-wire configuration to the ADM
module
To operate sensors without sense wires (4-wire mode), jumpers must be fitted
on terminal TE1 between pins 1 and 3 and 2 and 4.
4.5.1
Connection cable for analog load cell
When laying scale connecting cables (analog load receptors) please note:
S
Use only suitable scale connecting cables: