Calibration
166
A4774-1.0
HBM: public
WTX110
11.3
Select group (
group 1-9
)
For more information on the keys necessary to access this menu group, go to
the
.
Menu
Key
Function
Select group 1-9
Select the parameter groups
Scroll between groups 1 - 9
1 Scale Parameters
Set weighing parameters
2 Calibration
Calibrate scale
3 Linearization
Linearize scale
4 Zero Adjust
Adjust zero range
5 Adaptation
Adapt to the environment
6 High Resolution
Display with 10 times
resolution
7 Reset
Reset parameters
8 Calculate Span
Calibrating without
weights
9 W&M Info
Check the approval
parameters
Save and return to main menu
Finalize selection
Save parameters?
Y
To save calibration data:
Y
Save data to EEPROM
N
Discard all changes