Unload Scale
Standard
WTX110 V#.#.#
< 3 seconds
< 3 seconds
Weight Storage
Logbook
Software ID
Products
error protocoll,
only info
Mastermode
note: alternative
access
Mode: Info
(zero offset)
Mode: Adapt
(several
filter settings)
General
Config.
Analog out
Config.
Digital IO
Config. Scale
Com6 (DWB)
Com1 (SIM1)
Com0 (Eth)
Digital IO
Print Formats
Limit switches
General Setup
Calibration
Calibrate Scale 1
Select Group 1 – 9
Config.
Test
Reset
Network
Backup
General
Interface
Mastermode
Application
Service Mode
Date: Entry
Time: Entry
…
Brightness
Password
Target weight
...
Filler configuration;
only available
in filler application
note: only if
ALI available
only info
parameter
exception: back to „Select Group 1 – 9“ with
not with the F1 button
note: adapted parameters
must be saved to be valid!
only available in
standard application
note: only
calibration
note: only if
ALI available
note: ETH
or USB option
required
note: if „W1“ jumper
is in position 1
only access,
no changes possible
Search Date
Id-No.
Weight not found
Language
Keyboard
Time Zone (1)
Time Zone (2)
Date (format only)
Time (format only)
Country Code
Decimal char.
Approval signs
Tare mode
Cont. out.
Light off (Min.)
Power off (Min.)
Power Supply
Serial No.
Digital IO
Serial IO
ADM
HBM
None
PIM
Modbus TCP
SIO
None
Scale
Reset Service
Mode Parameters?
Reset
Approved Wgt
Non
DAU15
...
Aout 1: Mode
Aout 1: Output
Aout 1: Calibration
2 Calibration
3 Linearization
4 Zero Adjust
5 Adaption
6 High
Resolution
7 Reset
8 Calculation
Span
9 W&M Info
1 Scale
Parameters
Geo Value
Calibrate Zero?
Calibrate Load?
New Fixpoint 1?
Motion Window
Motion Counter
Filter Size
Auto Zero Range
...
Incline Switch
PowerUp Zero
With Taring?
Underload
Update Rate
1.
Connect Sensor
2.
go to “Calibration”\“1 Scale Parameters”
and enter load cell parameters like Capacity, Interval, Unit
3.
Perform Calibration
- with Calibration Weight go to “2 Calibration”
- without Calibration Weight go to “8 Calculation Span”
4.
Enter further parameters like Dual Range, Linearization, etc.
5.
Save Calibration Parameters
Weight
Reset Parameters?
Calibrate Zero?
Zero (mV/V)
LC-Cap. (kg)
No. of LCs
mV/V of LC1
W&M Setup ok
IP
Mask
Gate
DNS
NTP
FTP pwd
PanelX access
Access number
Set PanelX password
Update SSL cert
Start auto ping
Terminal No.
Backup or
Restore
from USB
Application
note: after
change restart
required!
Language
LS1 – LS4 Source
LS1 – LS4 Mode
Input 1 – 4
Output 1 – 4
Ticket Weight
Total Weight
Ticket Count
Total Count
Factory defaults
Load application
Baud
Databits
Parity
Ctrl.
Protcl.
Baud
Databits
Parity
Ctrl.
Protcl.
Port
Protocol
Entry field F1 button level
Two different possible entries
Map symbology
Subsequent field F1 button level
Related fields on F1 button level
Enter password / Unload Scale
Mastermode
Click F1 button
F1
F2
F3
F4
F5
Click respective grey button
Notes
Triple Range
Dual Range
Single Range
High Cap.
High Int.
Low Cap.
Low Int.
Unit
High Cap.
High Int.
Mid Cap.
Mid Int.
Low Cap.
Low Int.
Unit
Three Intervals
Two Intervals
One Interval
High Cap.
High Int.
Low Cap.
Low Int.
Unit
Capacity
Interval
Unit
High Cap.
High Int.
Mid Cap.
Mid Int.
Low Cap.
Low Int.
Unit
Three Intervals T+
Two Intervals T+
High Cap.
High Int.
Low Cap.
Low Int.
Unit
High Cap.
High Int.
Mid Cap.
Mid Int.
Low Cap.
Low Int.
Unit
3_ ...
2_ ...
1_...
ID: ...
MAC-/IP-Address
M:
IP:
Password
Enter service
password
1
Service
Appl.
Master
2
Entry
Supervisor
Mode
measure and predict with confidence
Quick Start Guide for Calibration Setup
WTX110
Navigation Pilot
Содержание WTX110
Страница 1: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 3: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 10: ...8 A4774 1 0 HBM public WTX110 17 Geo values 212...
Страница 55: ...Installation WTX110 A4774 1 0 HBM public 53 Fig 4 12 Positioning of ALI option on the WTX110 motherboard...
Страница 217: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 224: ...8 A4774 1 0 HBM public WTX110 17 Geowerte 217...
Страница 259: ...Installation WTX110 A4774 1 0 HBM public 43 Abb 4 6 Positionierung DIO Modul SIO auf der WTX110 Hauptplatine...
Страница 271: ...Installation WTX110 A4774 1 0 HBM public 55 Abb 4 12 Positionierung Alibi Speicher auf WTX110 Hauptplatine...