M2M.GEMALTO.COM

Cinterion

®

 Java Terminals

Hardware Interface Overview

Version:

03

DocId:

EHSxT_BGS5T_HIO_v03

Содержание Cinterion BGS5T USB

Страница 1: ... M2M GEMALTO COM Cinterion Java Terminals Hardware Interface Overview Version 03 DocId EHSxT_BGS5T_HIO_v03 ...

Страница 2: ...THE CONTEXT OF THE DELIV ERY OF THE PRODUCT THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW Copyright Transmittal reproduction dissemination and or editing of this document as well as utilization of its con tents and communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by paten...

Страница 3: ...g Modes 22 3 4 RS 232 Interface 23 3 4 1 9 Pole D sub Connector 23 3 5 USB Interface 24 3 6 GPIO Interface 24 3 6 1 Serial Interface ASC1 27 3 6 2 Digital Audio Interface 28 3 6 3 I2 C Interface 29 3 6 4 SPI Interface 30 3 6 5 PWM Interface 31 3 6 6 Pulse Counter 31 3 6 7 Analog to Digital Converter ADC 31 3 6 8 DSR0 signal 31 3 7 Ethernet Interface 32 3 8 Power Supply 33 3 9 Power Up Power Down S...

Страница 4: ... of 50 4 Mechanics Mounting and Packaging 40 4 1 Mechanical Dimensions 40 4 2 Mounting the Java Terminals 43 4 3 Packaging 44 5 Full Type Approval 45 5 1 Gemalto M2M Reference Setup 45 5 2 Restrictions 46 5 3 CE Conformity 46 5 4 EMC 46 5 5 Compliance with FCC and IC Rules and Regulations 47 6 List of Parts and Accessories 49 ...

Страница 5: ... the People s Republic of China 13 Table 8 Toxic or hazardous substances or elements with defined concentration limits 13 Table 9 Java Terminals label information 16 Table 10 Java Terminals interfaces 20 Table 11 Overview of operating modes 22 Table 12 9 pole D sub female RS 232 23 Table 13 GPIO connector pin availability and alternate pin functionalities 26 Table 14 Overview of DAI PCM signals 28...

Страница 6: ...ctors 8 pin and 12 pin 25 Figure 7 BGS5T USB GPIO connectors 8 pin and 12 pin 25 Figure 8 Long frame PCM timing 256kHz 28 Figure 9 Characteristics of SPI modes 30 Figure 10 8 pole RJ 45 Ethernet connector female 32 Figure 11 6 pole Western jack for power supply ignition reset typical connection 33 Figure 12 SIM interface 37 Figure 13 Status LED 38 Figure 14 Antenna connector 39 Figure 15 Java Term...

Страница 7: ... Hardware Interface Overview Version 03 Preceding document Cinterion Java Terminals Hardware Interface Overview Version 01 New document Cinterion Java Terminals Hardware Interface Overview Version 02 New document Cinterion Java Terminals Hardware Interface Overview Version 01 Chapter What is new 1 4 Revised Table 9 3 7 Added support for Power over Ethernet PoE Chapter What is new Throughout docume...

Страница 8: ...tern jack as plug in power supply connector BGS5T USB contains a Cinterion BGS5 module and implements a USB 2 0 interface with a USB B connector and also a V 24 V 28 RS 232 interface with a D sub 9 pole female socket as well as a 6 pole Western jack as plug in power supply connector Wherever necessary and appropriate this document distinguishes between these five variants Table 1 gives a short ove...

Страница 9: ...nd BTS Base Transceiver Station CB Cell Broadcast CODEC Coder Decoder DAI Digital Audio Interface DCE Data Circuit terminating Equipment DSR Data Set Ready DTR Data Terminal Ready EFR Enhanced Full Rate EGSM Enhanced GSM EMC Electromagnetic Compatibility ESD Electrostatic Discharge ETS European Telecommunication Standard FDMA Frequency Division Multiple Access G C F GSM Conformity Forum GSM Global...

Страница 10: ...ture Coefficient PA Power Amplifier PCB Printed Circuit Board PCM Pulse Code Modulation PCS Personal Communication System PD Power Down PDU Protocol Data Unit PoE Power over Ethernet R TTE Radio and Telecommunication Terminal Equipment RF Radio frequency RI Ring Indication RX Receive direction SIM Subscriber Identification Module SMS Short Message Service SW Software TDD Time Division Duplex TDMA ...

Страница 11: ...nt and of the Council of 8 December 2003 amending directive 2002 96 ec on waste electrical and electronic equipment WEEE Table 4 Standards of North American type approval CFR Title 47 Code of Federal Regulations Part 15 B Part 22 and Part 24 Telecom munications PCS US Equipment Authorization FCC OET Bulletin 65 Edition 97 01 Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofreq...

Страница 12: ...ty EMC standard for radio equipment and ser vices Part 24 Specific conditions for IMT 2000 CDMA Direct Spread UTRA for Mobile and portable UE radio and ancillary equipment ETSI EN 301 908 01 V5 2 1 Electromagnetic compatibility and Radio spectrum Matters ERM Base Stations BS and User Equipment UE for IMT 2000 Third Generation cellular networks Part 1 Harmonized EN for IMT 2000 introduction and com...

Страница 13: ...6 06 SJ T 11364 2006 Marking for Control of Pollution Caused by Electronic Information Products 2006 06 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the product is ...

Страница 14: ...cemaker while it is on This personal subgroup always should check the distance to the mobile Switch off the cellular terminal or mobile before boarding an aircraft Make sure it cannot be switched on inadvertently The operation of wireless appliances in an air craft is forbidden to prevent interference with communications systems Failure to observe these instructions may lead to the suspension or d...

Страница 15: ... area with adequate cellular signal strength Some networks do not allow for emergency calls if certain network services or phone features are in use e g lock functions fixed dialing etc You may need to deactivate those features before you can make an emergency call Some networks require a valid SIM card to be properly inserted in the cellular ter minal or mobile If a power supply unit is used to s...

Страница 16: ...EE symbol see Table 3 10 Chinese RoHS symbol see Table 7 11 CE logo with fixed notified body number May be replaced for samples with Not for sale see also Section 5 3 12 FCC Declaration of Conformity DoC logo BGS5T USB EHS6T LAN only with EHS6T LAN a smaller FCC logo is placed between bar code and Chinese RoHS symbol 13 FCC ID for Java Terminal EHS5T US RS485 EHS6T USB or FCC and IC ID EHS6T LAN 1...

Страница 17: ... class Small MS Output power according to Release 99 V5 depending on frequency band supported by mod ule Class 4 33dBm 2dB for EGSM850 Class 4 33dBm 2dB for EGSM900 Class 1 30dBm 2dB for GSM1800 Class 1 30dBm 2dB for GSM1900 Class E2 27dBm 3dB for GSM 850 8 PSK Class E2 27dBm 3dB for GSM 900 8 PSK Class E2 26dBm 3 4dB for GSM 1800 8 PSK Class E2 26dBm 3 4dB for GSM 1900 8 PSK Class 3 24dBm 1 3dB f...

Страница 18: ...S 1 4 MCS 1 9 SRB loopback and test mode B 8 bit 11 bit RACH PBCCH support 1 phase 2 phase access procedures Link adaptation and IR NACC extended UL TBF Mobile Station Class B CSD V 110 RLP non transparent 2 4 4 8 9 6 14 4kbps USSD SMS Point to point MT and MO Cell broadcast Text and PDU mode Software AT commands Hayes 3GPP TS 27 007 TS 27 005 Gemalto M2M Java Open Platform Java Open Platform with...

Страница 19: ...header with GPIO interface external power sup ply serial interface ASC1 ADC DAI PCM SPI I C and RS 485 option depending on variant Ethernet 8 pole RJ 45 Ethernet connector Support for Power over Ethernet PoE Power connector 6 pole Western connector female for power supply ignition power down signal SIM card reader Supported SIM cards 3V 1 8V Antenna Antenna connected via female SMA connector Power...

Страница 20: ... Terminals interfaces No Description 1 6 pin Western connector female for power supply ignition power down signal 2 8 pin female RJ 45 Ethernet connector 3 9 pin female D sub connector RS 232 interface 4 SMA connector female for GPS antennas for future use currently not available 5 SIM card reader 6 SMA connector female for RF antenna 7 SMA connector female for Rx diversity antenna for future use ...

Страница 21: ...figuration that incorporates a Java Terminal and typical accessories Figure 3 Block diagram Java Terminal Java module RS 232 driver USB SIM card interface Power regulation RF antenna interface LEDs RF antenna interface Host controller Power supply External application Power supply SIM card Antenna IGT_IN RST_IN GPIO driver interface Ethernet interface EHS6T LAN only Not for EHS6T LAN Not for EHS5T...

Страница 22: ...multis lot settings Watchdog active GPRS DATA GPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates GPRS configuration e g used multislot settings and reduction of maximum out put power Watchdog active EGPRS DATA EHSxT only EGPRS data transfer in progress Power consumption depends on network settings e g power control level ...

Страница 23: ...RS 232 D sub 9 pole female Java Terminals are designed for use as a DCE Based on the conventions for DCE DTE con nections it communicates with the customer application DTE using the following signals Port TxD application sends data to TXD0 of the Java Terminals Port RxD application receives data from RXD0 of the Java Terminals Hardware handshake using the RTS0 and CTS0 signals and XON XOFF softwar...

Страница 24: ... High Speed 480Mbit s device interface that is Full Speed 12Mbit s compliant The USB interface can be used as command and data interface and for downloading Java module firmware It is only available as a slave device and not able to act as a USB host 3 6 GPIO Interface The GPIO connectors 8 pin and 12 pin provide access to various module signals including a number of configurable GPIOs Note that n...

Страница 25: ...1 2 3 4 1 2 3 4 5 6 GPIO6 GPIO7 GPIO8 GPIO11 VCCref GND TXD1 SPI_MISO RXD1 SPI_MOSI CTS1 RS232 SPI_CS RTS1 RS232 5 6 7 8 7 8 9 10 11 12 GPIO12 GPIO13 GPIO22 GPIO23 5Vout DSR0 ADC1_IN SPI_CLK I2CDAT I2CCLK GPIO20 GPIO21 EHS6T USB LAN n a not applicable 1 2 3 4 1 2 3 4 5 6 GPIO6 GPIO7 GPIO8 n a VCCref GND TXD1 RXD1 CTS1 RS232 RTS1 RS232 5 6 7 8 7 8 9 10 11 12 n a n a GPIO22 GPIO23 5Vout DSR0 ADC1_IN...

Страница 26: ...figurable via AT command 7 GPIO22 Configurable via AT command also as TFSDAI 8 GPIO23 Configurable via AT command also as SCLK 12 pin connector 1 VCCref Input supply for level adjust ment E g connect 5Vout for 5V IO operation 2 GND 3 TXD1 or SPI_MISO Configurable via AT command also as SPI_MISO signal TXD1 TXD1 SPI_MISO TXD1 SPI_MISO TXD1 4 RXD1 or SPI_MOSI Configurable via AT command also as SPI_...

Страница 27: ...s and may thus lead to a higher current consumption Also be sure not to activate SLEEP mode e g by setting AT SPOW with mode 2 for the EHS5 module as the module may no longer be able to wake up from SLEEP mode and will then have to be reset 3 6 1 Serial Interface ASC1 With EHS5T and EHS6T Java Terminals two respectively four pins at the GPIO connector can be configured as ASC1 interface signals to...

Страница 28: ...ace signals TXDDAI RXDDAI TFSDAI and SCLK see also Table 13 The configuration is done by AT SCFG command see 1 It is non volatile and becomes active after a module restart DAI PCM and GPIO functionalities for these lines are mutually exclusive Table 14 describes the available DAI PCM lines at the digital audio interface1 Figure 8 shows the PCM timing for the master mode available with Java Termina...

Страница 29: ...d to the bus is software addressable by a unique 7 bit address and simple master slave relationships exist at all times The Java module operates as master transmitter or as master receiver An external application transmits or receives data only on request of the module To configure and activate the I2C bus use the AT SSPI command Detailed information on the AT SSPI command as well explanations on ...

Страница 30: ...Table 13 The configuration is done by AT com mand see 1 It is non volatile and becomes active after a module restart To configure and activate the SPI interface use the AT SSPI command Detailed information on the AT SSPI command as well explanations on the SPI modes required for data transmis sion can be found in 1 SPI ADC1_IN and DSR0 functionalities are mutually exclusive In general SPI supports...

Страница 31: ... AT SCFG command see 1 The pulse counter interface is an input line and can be used for example as a clock see also Table 13 GPIO and COUNTER functionalities are mutually ex clusive1 3 6 7 Analog to Digital Converter ADC ADC1_IN can be used for general purpose voltage measurements ADC1_IN is configured and read by the AT SRADC command see 1 ADC1_IN DSR0 and SPI functionalities are mu tually exclus...

Страница 32: ... Java Terminal firmware releases module firmware as well as Ethernet sub system software and also to access the implemented EHS6 module via AT command interface The Ethernet interface supports Power over Ethernet PoE according to IEEE standard 802 3 This means that if connected to a PoE enabled router or PoE injector the EHS6T LAN does no longer need a separate power supply unit such as the mains ...

Страница 33: ...for 1ms Java Terminals reset or switch off The watchdog can be configured to restart the Java Terminals When power fails for 15s the RTC will be reset Figure 11 6 pole Western jack for power supply ignition reset typical connection 1 As an alternative to the power supply via Western jack Power over Ethernet PoE can be employed The PoE feature complies with IEEE 802 3 standards and can be made avai...

Страница 34: ...nd GND of the 6 pole Western jack If using the PoE feature EHS6T LAN can also be started up by connecting simply the Ethernet interface If switched off i e while in Power Down mode Java Terminals can be started up by activating the IGT_IN signal pin 4 Java Terminals can be started up by activating the RS 232 DTR line as long as RST_IN signal pin 3 is not active voltage 2V Java Terminals can be sta...

Страница 35: ...an disconnecting the mains adapter This switch off procedure lets the Java Terminals log off from the network and allows the software to enter a secure state and save data before disconnecting the power supply After AT SMSO has been entered the Java Terminals returns the following result codes SMSO MS OFF OK SHUTDOWN The SHUTDOWN result code indicates that the Java Terminals turns off in less than...

Страница 36: ...Java Terminals feature a programmable hardware watchdog that permanently monitors the terminals hardware and can be configured to react to various hardware states The watch dog may for example be configured to periodically restart the terminal independent of its cur rent operating state 3 12 RTC The internal Real Time Clock RTC of the Java Terminals retains the time and date and han dles the alarm...

Страница 37: ...idental removal The SIM can be removed from the card holder by using a flat object such as a screwdriver to carefully press the inserted SIM until it snaps out again All signals of the SIM interface are protected from electrostatic discharge Removing and inserting the SIM card during operation requires the software to be reinitialized Therefore after reinserting the SIM card it is necessary to res...

Страница 38: ... semitransparent cas ing A green LED indicates whether the Java Terminals are ready to operate and reports certain watchdog operations A yellow LED indicates the network registration state of the Java Terminals Figure 13 Status LED The yellow LED can be configured by using the AT SLED command to either light permanently or to flash For details on the AT command please refer to 1 Green LED Power on...

Страница 39: ...ESD protection to the antenna connector is provided No DC voltage must be applied to the antenna circuit to protect it from damage Please note that the terminal should be installed and operated with a minimum distance of 20cm between the antenna connected to the terminal and any human bodies Also the trans mitter must not be co located or operating in conjunction with any other antenna or transmit...

Страница 40: ...aging 4 1 Mechanical Dimensions Figure 15 shows a 3D view of the Java Terminal and provides an overview of the mechanical dimensions of the board For further details see Figure 16 and Figure 17 Figure 15 Java Terminals 3D overview Length 113 5mm including fixtures for cable straps Width 75mm excluding antenna and serial interface connectors Height 25 5mm Weight 120g 113 5mm 75mm 25 5mm ...

Страница 41: ...Cinterion Java Terminals Hardware Interface Overview 4 1 Mechanical Dimensions 44 EHSxT_BGS5T_HIO_v03 2016 05 26 Confidential Released Page 41 of 50 Figure 16 Java Terminals mechanical dimensions ...

Страница 42: ...Cinterion Java Terminals Hardware Interface Overview 4 1 Mechanical Dimensions 44 EHSxT_BGS5T_HIO_v03 2016 05 26 Confidential Released Page 42 of 50 Figure 17 Java Terminals exploded view ...

Страница 43: ...30 format A catch at the terminal s bottom side will have to be removed to slide multiple terminals onto a single rail Using a BOPLA TSH 35 2 universal DIN rail holder the Java Terminals can be fitted onto another special type of DIN rail made according to DIN EN 60715 Top hat section 35mm e g Wago 210 113 steel carrier rail The following figure shows the various possibilities provided to mount th...

Страница 44: ...a Terminals Hardware Interface Overview 4 3 Packaging 44 EHSxT_BGS5T_HIO_v03 2016 05 26 Confidential Released Page 44 of 50 4 3 Packaging Java Terminals come in terminal boxes Terminal box size 191mm x 143mm x 44mm ...

Страница 45: ...Reference Setup The Gemalto M2M reference setup submitted to type approve Java Terminals consists of the following components Java Terminals with approved Java module PC as MMI Power Supply Figure 19 Reference equipment for approval For ordering information please refer to Chapter 6 PC Power supply SIM RS 232 USB LAN Java Terminal Antenna or 50Ohm cable to the system simulator ARP ...

Страница 46: ...that comply with the approved Java Terminals configuration Extra approval must be obtained for applications using other accessories than those included in the approved Java Terminals configuration power supply MMI implementation supported by AT commands 5 3 CE Conformity The Java Terminals meet the requirements of the EU directives listed below R TTE Directive 1999 5 EC The Java Terminals are mark...

Страница 47: ...may cause undesired operation This terminal equipment has been tested and found to comply with the limits for a Class B dig ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reason able protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor ...

Страница 48: ...nnement EN Radio frequency RF Exposure Information The radiated output power of the Wireless Device is below the Industry Canada IC radio fre quency exposure limits The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized This device has also been evaluated and shown compliant with the IC RF Exposure limits un der mobile exp...

Страница 49: ...ly Ordering number L36880 N8490 A15 DIN rail holder BOPLA TSH 35 2 BOPLA Ordering number 20035000 BOPLA Gehäuse Systeme GmbH Borsigstr 17 25 D 32257 Bünde Phone 49 0 5223 969 0 Fax 49 0 5223 969 100 Email info bopla de Web http www bopla de Antenna SMARTEQ MiniMAG Dualband 0dBd 2 6m RG174 SMA m KÖBEL Mobile Communication Ordering number 1140 26 with crimped SMA connector KÖBEL Mobile Communication...

Страница 50: ...privacy protection eHealthcare and eGovernment efficiency convenient ticketing and dependable machine to machine M2M applications Gemalto develops secure embedded software and secure products which we design and personalize Our platforms and services manage these secure products the confidential data they contain and the trusted end user services they enable Our innovations enable our clients to o...