Supervisormode
WTX110
A4774-1.0
HBM: public
151
Information
Choose an increase in weight that is greater than the fluctuations caused by
the material escaping during the filling process.
When a break is detected:
S
Coarse flow and fine flow are deactivated.
S
if bit 6 (Alarm) is set to 1 in dosing status (SDO),
S
then if Alarm:Fill flow On is set, the alarm is triggered,
S
dosing control goes to stop status.
10.2.30 Lock out time fine flow (
Lock fine(s)
)
The time starts when the coarse flow cut-off point is reached. For the specified
time, the comparison of the actual weight against reaching of the fine flow cut-
off point is disabled. The time does not delay the filling process.
When the coarse flow shuts off, settling processes may occur that will already
cause the coarse flow cut-off point to be exceeded. You can prevent that with
this setting. Experience shows that the lockout time should be about 10 % of
the fine flow dosing time.
Содержание WTX110
Страница 1: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 3: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 10: ...8 A4774 1 0 HBM public WTX110 17 Geo values 212...
Страница 55: ...Installation WTX110 A4774 1 0 HBM public 53 Fig 4 12 Positioning of ALI option on the WTX110 motherboard...
Страница 217: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Страница 224: ...8 A4774 1 0 HBM public WTX110 17 Geowerte 217...
Страница 259: ...Installation WTX110 A4774 1 0 HBM public 43 Abb 4 6 Positionierung DIO Modul SIO auf der WTX110 Hauptplatine...
Страница 271: ...Installation WTX110 A4774 1 0 HBM public 55 Abb 4 12 Positionierung Alibi Speicher auf WTX110 Hauptplatine...