Application
WTX110
A4774-1.0
HBM: public
121
Function/Secondary selection
Key
Menu
Output 1…4
The following functional settings are available for
configuration of the digital outputs:
Off
Deactivated
Manual
Manual set/reset via
Service Mode/Test
(see 16.4.3)
Coarse
When activated, the coarse flow
valve is opened.
Fine
When activated, the fine flow valve
is opened.
Ready
When active, signals that the filling
process is complete.
Tol.+
Signals tol has been
exceeded
Tol.-
Signals tolerance - has not been
reached
Tol. Error
Signals tol has been
exceeded or tolerance - has not
been reached
DL1/DL2
When the DL1/DL2 phase is
activated, the output is activated
during DL2
Discharge
During the discharge phase
(weight and/or time controlled) the
relevant discharge actuator is
activated
Содержание WTX110