1-19
[SwitchC] interface vlan-interface 2
[SwitchC-Vlan-interface2] ntp-service broadcast-server
2) Configuration on Switch D:
# Configure Switch D to work in the broadcast client mode and receive broadcast messages on
VLAN-interface 2.
<SwitchD> system-view
[SwitchD] interface vlan-interface 2
[SwitchD-Vlan-interface2] ntp-service broadcast-client
3) Configuration on Switch A:
# Configure Switch A to work in the broadcast client mode and receive broadcast messages on
VLAN-interface 3.
<SwitchA> system-view
[SwitchA] interface vlan-interface 3
[SwitchA-Vlan-interface3] ntp-service broadcast-client
Because Switch A and Switch C are on different subnets, Switch A cannot receive the broadcast
messages from Switch C. Switch D gets synchronized upon receiving a broadcast message from
Switch C.
# View the NTP status of Switch D after clock synchronization.
[SwitchD-Vlan-interface2] display ntp-service status
Clock status: synchronized
Clock stratum: 3
Reference clock ID: 3.0.1.31
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^18
Clock offset: 0.0000 ms
Root delay: 31.00 ms
Root dispersion: 8.31 ms
Peer dispersion: 34.30 ms
Reference time: 16:01:51.713 UTC Sep 19 2005 (C6D95F6F.B6872B02)
As shown above, Switch D has been synchronized to Switch C, and the clock stratum level of Switch D
is 3, while that of Switch C is 2.
# View the NTP session information of Switch D, which shows that an association has been set up
between Switch D and Switch C.
[SwitchD-Vlan-interface2] display ntp-service sessions
source reference stra reach poll now offset delay disper
**************************************************************************
[1234] 3.0.1.31 127.127.1.0 2 254 64 62 -16.0 32.0 16.6
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations : 1
Configuring NTP Multicast Mode
Network requirements
z
Switch C’s local clock is to be used as a reference source, with the stratum level of 2.