background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 

 

 

BNI EIP-950-000-Z009 

IP67 Module, Unmanaged Switch 

User’s Guide 

Содержание BNI EIP-950-000-Z009

Страница 1: ...BNI EIP 950 000 Z009 IP67 Module Unmanaged Switch User s Guide ...

Страница 2: ...2 2 Installation and startup 3 2 3 General safety notes 3 Hazardous voltage 3 3 Getting started 3 1 Connection overview 4 3 2 Mechanical connection 5 3 3 Electrical connection 5 3 4 Ethernet connection 5 4 Technical data 4 1 Dimensions 6 4 2 Mechanical data 6 4 3 Operating conditions 6 4 4 Electrical data 6 4 5 Ethernet port 7 4 6 LED indicators 7 Appendix Product ordering code 8 Order information...

Страница 3: ...The main steps for installing the device Section 4 Technical data for the device 1 3 Typographical conventions The following typographical conventions are used in this guide Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate where further information on t...

Страница 4: ...on the function of the device Authorized Personnel Installation and commissioning may only be performed by trained specialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device...

Страница 5: ... 3 1 Connection overview 1 Mounting hole 2 Ethernet Port 5 3 Status LED transmission rate 4 Ethernet Port 6 5 Status LED Link active 6 Ethernet Port 7 7 Ethernet Port 8 8 Ethernet Port 4 9 Ethernet Port 3 10 Ethernet Port 2 11 Ethernet Port 1 12 Label 13 Power supply 14 Ethernet Uplink Port 1 1 2 7 3 4 5 6 8 11 10 12 13 9 14 ...

Страница 6: ...i 4 pin plug PIN Signal Demand 1 24 V Power 1 2 24 V Power 2 3 0 V Power 2 Common GND 4 0 V Power 1 Common GND 24 V DC Total current 9A The total current of all modules may not exceed 9A even when daisy chaining the actuator supply Function earth Figure 3 2 FE connection Note The FE connection from the housing to the machine must be low impedance and kept as short as possible 3 4 Ethernet connecti...

Страница 7: ...y voltage 7 8 4 pin male Dimensions W x H x D in mm 68 x 224 x 32 4 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 580gr 4 3 Operating conditions Operating temperature Ta Storage temperature 5 C 55 C 25 C 75 C EMC Immunity Emission EMC directive 2004 108 EEC EN 61000 6 2 EN 61000 6 4 Shock vibration EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 EN 60068 2 64 4 4 Electrical da...

Страница 8: ...low control Half Duplex Full Duplex IEEE 802 33x Pause 4 6 LED indicators LED indicators Ethernet IP module LED Indicator Function LED 1 Green Red Power Status LED 4 Red Off Module Status LED 7 Yellow Off Data transfer Uplink port active inactive LED 9 Yellow Off Data trans rate Uplink port 100Mbit s 50 Mbit s LED indicators ports Each M12 port is assigned LEDs which indicate the configuration or ...

Страница 9: ...switch Variant 000 Standard version Mechanical version Z009 Material Die cast zinc housing Uplink 1 x M12x1 internal thread Power 7 8 external thread Ethernet ports 8 x M12x1 internal thread Order information Product ordering code Order code BNI EIP 950 000 Z009 BNI000F Scope of delivery The BNI EIP consists of the following components IO block 4 blind plugs M12 Ground strap Screw M4x6 20 labels U...

Страница 10: ...Balluff Network Interface EtherNet IP BNI EIP 950 000 Z009 www balluff com 9 Notes ...

Страница 11: ...Balluff Network Interface EtherNet IP BNI EIP 950 000 Z009 www balluff com 10 Notes ...

Страница 12: ...P BNI EIP 950 000 Z009 www balluff com 11 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de www balluff com Nr 910590 E Edition 1312 Subject to modification ...

Отзывы: