1-16
Task
Remarks
Configuring an MST Region
Required
Configuring the Work Mode of an MSTP Device
Optional
Configuring the Timeout Factor
Optional
Configuring the Maximum Port Rate
Optional
Configuring Ports as Edge Ports
Optional
Configuring Path Costs of Ports
Optional
Configuring Port Priority
Optional
Setting the Link Type of a Port to P2P
Optional
Configuring the Mode a Port Uses to Recognize/Send
MSTP Packets
Optional
Enabling the Output of Port State Transition Information
Optional
Configuring Leaf
Nodes
Enabling the MSTP Feature
Required
Performing mCheck
Optional
Configuring the VLAN Ignore Feature
Optional
Configuring Digest Snooping
Optional
Configuring No Agreement Check
Optional
Configuring Protection Functions
Optional
z
If both GVRP and MSTP are enabled on a device at the same time, GVRP packets will be
forwarded along the CIST. Therefore, if you wish to advertise a certain VLAN within the network
through GVRP in this case, make sure that this VLAN is mapped to the CIST (MSTI 0) when
configuring the VLAN-to-MSTI mapping table. For the detailed information of GVRP, refer to
GVRP
Configuration
of the
Access Volume
.
z
MSTP is mutually exclusive with Smart Link on a port.
z
Configurations made in Layer-2 aggregate interface view can take effect only on the aggregate
interface; configurations made on an aggregation member port can take effect only after the port is
removed from the aggregation group. For detailed information about link aggregation, refer to
Link
Aggregation Configuration
in the
Access Volume
.
z
After you enable MSTP on a Layer-2 aggregate interface, the system performs MSTP calculation
on the Layer-2 aggregate interface but not on the aggregation member ports. The MSTP enable
state and forwarding state of each selected port in an aggregation group is consistent with those of
the corresponding Layer-2 aggregate interface.
z
Though the member port of an aggregation group does not participate in MSTP calculation, the
port still reserves its MSTP configurations for participating MSTP calculation after leaving the
aggregation group.