Configuration procedure
1) Configure the master device
# Configure a private IP address pool for the stack on Switch A.
<SwitchA> system-view
[SwitchA] stack ip-pool 192.168.1.1 24
# Configure port Ten-GigabitEthernet1/0/51 as a stack port on Switch A.
[SwitchA] stack stack-port 1 port ten-gigabitethernet 1/0/51
# Configure switch A as the master device.
[SwitchA] stack role master
2) Configure the slave devices
# On Switch B, configure local ports Ten-GigabitEthernet 1/0/52 and Ten-GigabitEthernet 1/0/51 as
stack ports.
<SwitchB> system-view
[SwitchB] stack stack-port 2 port ten-gigabitethernet 1/0/51 ten-gigabitethernet 1/0/52
# On Switch C, configure local port Ten-GigabitEthernet 1/0/51 and Ten-GigabitEthernet 1/0/52 as a
stack port.
<SwitchC> system-view
[SwitchC] stack stack-port 2 port ten-gigabitethernet 1/0/51 ten-gigabitethernet 1/0/52
# On Switch D, configure local port Ten-GigabitEthernet 1/0/51 as a stack port.
<SwitchD> system-view
[SwitchD] stack stack-port 1 port ten-gigabitethernet 1/0/51
3) Verify the configuration
# Display stack information of the stack members on Switch A.
<stack_0.SwitchA> display stack members
Number : 0
Role : Master
Sysname : stack_0. SwitchA
Switch type: S5810-50S
MAC address: 000f-e200-1000
Number : 1
Role : Slave
Sysname : stack_1. SwitchB
Device type: S5810-50S
MAC address: 000f-e200-1001
Number : 2
Role : Slave
Sysname : stack_2. DeviceC
Device type: S5810-50S
MAC address: 000f-e200-1002
Number : 3
Содержание S5810 Series
Страница 307: ...ii Configured Multicast Group Policy Fails to Take Effect 1 32...
Страница 648: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...