1-41
# Configure the user interfaces to support SSH.
[Switch-ui-vty0-4] protocol inbound ssh
[Switch-ui-vty0-4] quit
# Configure the RADIUS scheme.
[Switch] radius scheme rad
[Switch-radius-rad] primary authentication 10.1.1.1 1812
[Switch-radius-rad] primary accounting 10.1.1.1 1813
[Switch-radius-rad] key authentication expert
[Switch-radius-rad] key accounting expert
[Switch-radius-rad] user-name-format with-domain
[Switch-radius-rad] quit
# Specify the service type for the RADIUS server, which must be
extended
when the RADIUS server
runs iMC.
[Switch-radius-rad] server-type extended
[Switch-radius-rad] quit
# Configure the AAA methods for the domain.
[Switch] domain bbb
[Switch-isp-bbb] authentication login radius-scheme rad
[Switch-isp-bbb] authorization login radius-scheme rad
[Switch-isp-bbb] accounting login radius-scheme rad
[Switch-isp-bbb] quit
When using SSH to log in, a user enters a username in the form userid@bbb for authentication using
domain
bbb
.
3) Verify the configuration
After the above configuration, the SSH user should be able to use the configured account to access the
user interface of the switch. The commands that the user can access depend on the settings for EXEC
users on the iMC server.
Troubleshooting AAA
Troubleshooting RADIUS
Symptom 1:
User authentication/authorization always fails.
Analysis:
1) A communication failure exists between the NAS and the RADIUS server.
2) The username is not in the format of userid@isp-name or no default ISP domain is specified for the
NAS.
3) The user is not configured on the RADIUS server.
4) The password of the user is incorrect.
5) The RADIUS server and the NAS are configured with different shared key.
Solution:
Check that:
1) The NAS and the RADIUS server can ping each other.
Содержание S5810 Series
Страница 307: ...ii Configured Multicast Group Policy Fails to Take Effect 1 32...
Страница 648: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...