1-8
[Sysname-GigabitEthernet1/0/2] port trunk permit vlan 20
[Sysname-GigabitEthernet1/0/2] quit
[Sysname] smart-link group 1
[Sysname-smlk-group1] protected-vlan reference-instance 0 to 8
[Sysname-smlk-group1] port gigabitethernet1/0/1 master
[Sysname-smlk-group1] port gigabitethernet1/0/2 slave
[Sysname-smlk-group1] flush enable control-vlan 20
[Sysname-smlk-group1] quit
Configuring an Associated Device
Enabling the Receiving of Flush Messages
You do not need to enable all ports on the associated devices to receive flush messages sent from the
transmit control VLAN, only those on the active and standby links between the smart link device and the
destination device.
For example, as all the numbered ports on Device A, B, and D in
Figure 1-1
are on the active or standby
links from Devices C and E to Device A, you need to enable the ports to process flush messages
received from the control VLAN configured on Device C and E.
Follow these steps to enable the receiving of flush messages:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter Ethernet interface view or
Layer 2 aggregate interface view
interface
interface-type
interface-number
—
Configure the control VLANs for
receiving flush messages
smart-link flush enable
[
control-vlan vlan-id-list
]
Required
By default, no control
VLAN exists for receiving
flush messages.
z
Configure all the control VLANs to receive flush messages.
z
If no control VLAN is specified for processing flush messages, the device forwards the received
flush messages without processing them.
z
Make sure that the receive control VLAN is the same as the transmit control VLAN configured on
the smart link device. If they are not the same, the associated device will forward the received flush
messages directly without any processing.
z
Do not remove the control VLANs. Otherwise, flush messages cannot be sent properly.
z
Make sure that the control VLANs are existing VLANs, and assign the ports capable of receiving
flush messages to the control VLANs.
Содержание S5810 Series
Страница 307: ...ii Configured Multicast Group Policy Fails to Take Effect 1 32...
Страница 648: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...