1-6
To do…
Use the command…
Remarks
Configure the GARP LeaveAll
timer
garp timer leaveall
timer-value
Optional
The default is 1000
centiseconds.
Enter Ethernet or
Layer 2
aggregate
interface view
interface interface-type
interface-number
Enter
Ethernet
interface
view, Layer
2 aggregate
interface
view, or
port-group
view
Enter port-group
view
port-group manual
port-group-name
Required
Perform either of the
commands.
Depending on the view you
accessed, the subsequent
configuration takes effect on a
port or all ports in a
port-group.
Configure the Hold timer
garp timer hold
timer-value
Optional
10 centiseconds by default
Configure the Join timer
garp timer join timer-value
Optional
20 centiseconds by default
Configure the Leave timer
garp timer leave timer-value
Optional
60 centiseconds by default
As shown in
Table 1-2
, the values of GARP timers are dependent on each other:
z
If you want to set a value beyond the value range for a timer, you may change the value range by
tuning the value of another related timer.
z
If you want to restore the default settings of the timers, restore the Hold timer first, and then the
Join, Leave, and LeaveAll timers.
Table 1-2
Dependencies of GARP timers
Timer
Lower limit
Upper limit
Hold 10
centiseconds
No greater than half of the Join timer
setting
Join
No less than two times the Hold timer
setting
Less than half of the leave timer setting
Leave
Greater than two times the Join timer
setting
Less than the LeaveAll timer setting
LeaveAll
Greater than the Leave timer setting
32765 centiseconds