Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
302
Appendix
Troubleshooting: Set the K012.7 to 0 retreating from the manipulator debugging mode.
Alarm information: 1264 Spindle position mode conversion abnormality (A008.0)
Fault reason: When performing the M29 code, there is no completion signal of the spindle position
mode within the setting time of the T24.
Troubleshooting: Regularize the setting time of the T24 or check whether the completion signal of
the spindle position mode is output.
Alarm information: 1265 Spindle velocity mode conversion abnormality (A008.1)
Fault reason: When performing the M28 code, there is no completion signal of the spindle velocity
mode within the setting time of the T28.
Troubleshooting: Regularize the setting time of the T28 or check whether the completion signal of
the spindle velocity mode is output.
Alarm information: 1267 Fail to operate because the tool case does not vertical to the manipulator
(A008.3)
Fault reason: The manipulator operation is performed when the tool case is not vertical.
Troubleshooting: Firstly perform the vertical operation of the tool case.
Alarm information: 1268 Fail to operate due to the manipulator does not at the origin (A008.4)
Fault reason: The manipulator operation is performed when it is not at the origin.
Troubleshooting: Set the K12.7 as 1, that is, the manipulator enters the debugging mode, return the
manipulator to the origin by the button of the tool-change.
Alarm information: 1269 Manipulator operation abnormal interruption (A008.5)
Fault reason: The manipulator operation is abnormally interrupted by pressing the ESP, RESET
button during the manipulator operation.
Troubleshooting: Set the K10.7 to 1, that is, tool magazine enters to the debugging mode, return the
manipulator to the origin in the manual mode.
Alarm information: 1270 Manipulator tool-hold detection abnormality (A008.6)
Fault reason: The manipulator can not reach to the tool-hold position within the setting time of the
T110 when it is performed the tool-hold operation; or the manipulator can not reach to
the tool-hold position within the setting time of the T111 when it descends to rotate
180 degree.
Troubleshooting: Check whether the output of the Y2.5 is normal.
Check whether the input of the X3.3 is normal.
Alarm information: 1271 Fail to operate the manipulator due to the spindle does not orientate
(A008.7)
Fault reason: Perform the manipulator operation when the spindle does not orientate.
Troubleshooting: Perform the spindle orientation at the first time.
Alarm information: 1272 Fail to operate the manipulator due to the spindle tool does not release