Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
174
V
o
lume IV
In
st
all
at
io
n
&
Co
nn
ect
io
n
2.2 Connection Between System and Drive Unit
The interfaces with the drive unit include XS30 (X axis), XS31 (Y axis), XS32 (Z axis) and XS33
(the 4
th
axis).
2.2.1 System Interface Figure
Fig. 2-2-1-1
2.2.2 Interface Signal List
Fig. 2-2-2-1
6
ZDIR+
2
6
8
7
0V
ZEN
4
5
3
+24V
ZDALM
ZPC
13
+5V
0V
0V
15
14
ZDIR-
0V
+5V
12
11
10
XS32:DB15 female(Z axis)
1
ZCP+
8
7
0V
XEN
ZCP-
9
0V
0V
15
14
XS30:DB15 female(X axis)
XDIR+
2
4
5
3
+24V
XDALM
XPC
1
XCP+
XDIR-
10
+5V
+5V
0V
13
12
11
XCP-
9
6
XS33:DB15 female(4
TH
axis)
4DIR+
2
4EN
4DALM
4PC
+24V
6
8
7
4
5
3
+5V
13
15
14
0V
0V
0V
12
11
10
+5V
4DIR-
0V
4CP+
YEN
1
8
7
9
4CP-
14
15
0V
0V
0V
YDALM
YPC
YDIR+
YCP+
XS31:DB15 female(Y axis)
+24V
2
4
5
3
1
YDIR-
10
11
12
13
+5V
+5V
0V
9
YCP-