Appendix II Laddar Diagram Use Guide of GSK218mc Series Matching with Disc Tool Magazine
305
Appendix
Alarm information: 1292 Do not move the index worktable because it is released. (A011.4)
Fault reason: When the index worktable is at the releasing state, the feed axis performs the
movement operation.
Troubleshooting: Firstly, perform the index worktable clamping operation, then perform the feed axis
that it executes the movement operation; or adjust the index worktable to the
debugging mode (that is: K12.6 is set to1), then perform the feed axis that it
executes the movement operation.
Alarm information: 1293 Do not perform the cycle start because the safety door is open (A011.5)
Fault reason: When the safety door detection equipment is used (that is, K8.3=1), the cycle start
button is controlled when the safety door does not close (that is: X4.5=0)
Troubleshooting: Perform the cycle start before closing the safety door.
Alarm information: 1294 Do not perform the shift in rigid tapping, it is better to cancel the rigid
tapping firstly, and then shift it. (A001.6)
Fault reason: Use the spindle shift equipment; Do not perform the M29 tapping command when shift
is not in-position.
Troubleshooting: Perform the shift before cancelling the rigid tapping
Alarm information: 1360 Low lubrication pressure or grease level (A020.0)
Fault reason:
Troubleshooting: Detect the state of X001.7
Precaution:
The alarm of the “User self-defined” in the fault cause, but this alarm does not
design in the ladder diagram, so it is better to add by altering the ladder diagram.
Table 5 The definition of the TMR parameter
Add. Note
Initial
value (ms)
User
setting
value (ms)
T001
Spindle positive completion delayer
500
T002
Spindle negative completion delayer
500
T003
Spindle shift completion delayer
500
T004 Spindle
positioning
completion delayer
0
T005
Miscellaneous function completion delayer
0
T006 Spindle
shift
delayer
500
T007
Spindle tool releasing completion delayer
0
T008
Spindle tool clamping completion delayer
0
T009
Spindle tool releasing detection time
8000
T010
Spindle tool clamping detection time
8000
T011
M code miscellaneous function delay completion
50
T012
T code miscellaneous function delay completion
50