Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
202
V
o
lume IV
Inst
allation
&
Connecti
o
n
X000.6
XS40
18
Stroke limit signal along
with the 4
th
axis
NC
contactor
2. Alter the following parameter
Table 4-3-4
Add.
Definition
State 0
State 1
Setting value
K006.0
Whether uses one limit switch
2pcs
1pc
1
State parameter
0
1
1
BFA
LZR
LZR
=1: Perform the stroke inspection after the power is turned on till to the
manual reference position return.
=0: Do not perform the stroke inspection after the power is turned on till to the
manual reference position return.
BFA
=1: Alarm occurs after the overtravel when the overtravel command issues.
=0: Alarm occurs before the overtravel when the overtravel command issues.
System parameter No.
0
3
1
G13
G13
=1: It is set as G13 mode when switches on the power or cleans the state.
=0: It is set as G12 mode when switches on the power or cleans the state.
System parameter No.
0
6
1
LALM
LALM
=1: Regardless of the hard limit alarm
=0: Regard the hard limit alarm.
4.4 Gear Ratio Adjustment
When the distance between the machine movement and the shifting one of displayed in the
system coordinate are inconsistent, the adjustment of the electric gear ratio can be altered by the
system parameter
P160
~
P164
and
P165
~
P169 for adapting different mechanical drive ratio.
Set the frequency-conversion of the position code pulse (Electric gear)
It is very convenient to match each pulse source by setting the parameter for the user’s ideal
control resolution (Angle/pulse) in the position control mode
Calculation formula: