Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC & Installation Connection Manual
86
Volume II
Operatio
n
3.4 Counter
Press the
[CTR]
soft key in the Fig. 3-1, then enter the checking and setting interface of the
counter, refer to the
Fig. 3-4-1
.
Fig. 3-4-1
The content and operation of the counter:
RUN :
The operation state of the ladder diagram.
N0. :
Serial number of the counter; Do not change it.
ADDR. :
Counter address; Do not change it.
CURT :
Current value of the counter; Do not change it.
SET :
Counter setting value; it can be changed after the K000.0 (PLC parameter allows
modification) is set to 1 in the MDI mode.
Input :
Input data display.
MDI mode :
Current working mode.
[Return] :
Return to the previous menu.
[
X
]
: Enter to the next page.
The set value can be downloaded to the CNC operation pressing the
<Save>
key after
modifying. “CTR downloading successful” displays after the save is performed; the system displays:
“downloading fail” when the save is incorrect; the “illegal downloading parameter” displays without
downloading conditions.
Note: It only can be saved and operated by pressing the [Save] key after modifying
The search and positioning can be performed by the page-up, page-down and four direction keys
on the panel; checking and modifying of the counter address can be performed.