Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
262
Appendix
positioning (A005.7)
Fault reason: There is no positioning for the spindle, perform the operation of the tool magazine
infeed.
Troubleshooting: Perform the spindle positioning.
Alarm information: 1248 Tool magazine can not be retracted in the tool releasing state (A006.0)
Fault reason: Perform the tool retraction operation in the state of the spindle tool releasing.
Troubleshooting: Clamp the spindle tool and then retract it.
Alarm information: 1249 Spindle is with cutter instead if infeed (A006.1)
Fault reason: Z axis is at the origin, and there is cutter (D245 is not set to 0) on the spindle, the tool
magazine infeed operation is then performed.
Troubleshooting: Disassemble the cutter on the spindle, set the D245 to 0.
Alarm information: 1250 Fail to infeed because the current tool number between the spindle and
tool magazine is different. (A006.2)
Fault reason: Z axis is at the tool-change position, the tool number on the spindle is different from
the one on the current tool case; the tool magazine infeed operation is executed.
Troubleshooting: Rotate the tool magazine so that the tool number on the current tool case is
identical with the one on the spindle.
Alarm information: 1251 Turn off the power (A006.3)
Fault reason: That the parameter can be enabled after the system is restarted again is altered.
Troubleshooting: Restart the system.
Alarm information: 1252 Clamp the tool, do not move the Z axis (A006.4)
Fault reason: When the tool magazine is on the infeed position, and the spindle tool is on the
clamping state, the Z axis movement is then preformed.
Troubleshooting: 1. Put the tool magazine is on the retraction position
2. Make the spindle tool is on the releasing state.
Alarm information: 1253 Carefully operate the tool magazine adjustment mode (A006.5)
Fault reason: This alarm occurs when K010.7 is set to 1, in this case, only prompts that the tool
magazine enters the debugging mode; it is necessary to carefully operate it because
the alarm and interlocking signal related with the tool magazine is fully released;
otherwise, the abnormality may occur, as well the machine may be damaged.
Troubleshooting: Clear this alarm by “Reset” button (Note: Clear this alarm means not that the
system is not on the tool magazine debugging mode. It is necessary to set the