GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
296
Appendix
Alarm information: 1228 Do not to perform the cycle start because the tool case on the vertical
position (A003.4)
Fault reason: If the tool case is on the vertical position, press the “Start” button in the Auto, MDI or
DNC mode, the alarm will occur.
Troubleshooting: Performing the tool case returns to the horizontal position.
Alarm information: 1229 Firstly perform the mechanical zero return before executing the M06 code
(A003.5)
Fault reason: Perform the M06 or M50 code before the zero return does not execute.
Troubleshooting: Perform the mechanical zero return at the first time.
Alarm information: 1230 Failure to tool-change in the spindle tool-releasing state (A003.6)
Fault reason: Perform the M06 or M50 code when the spindle tool is at the releasing state (Y0.2=1).
Troubleshooting: Performing the spindle tool is at the clamping state (Y0.2=0).
Alarm information: 1231 Failure to tool-change because the tool case does not at the horizontal
position (A003.7)
Fault reason: Perform the M06 or M50 code when the tool case does not at the horizontal position.
Troubleshooting: Performing the tool case returns to the horizontal position.
Alarm information: 1232 Tool magazine rotation in-position detection abnormality (A004.0)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1233 Tool rotation motor overload (A004.1)
Fault reason: The machinery in the operation processing is chucked or excessive big for the current
when the tool magazine rotates the motor, the motor overload may cause.
Troubleshooting: Check whether the machinery of the tool magazine motor rotation is normal. Close
the overload protective switch of the machinery tool magazine motor rotation
again on the electric cabinet after the abnormality is removed.
Alarm information:1234 Mechanical arm motor overload (A004.2)
Fault reason: The machinery is chucked or the current is excessive big during the mechanical arm is
performed, it may cause the overload of the motor.
Troubleshooting: Check whether the manipulator of the machine is normal. Close the overload
protective switch of the machinery arm motor again on the electric cabinet after