4.12 External Editing Lock and the External Operation Panel Lock
z
Relative
signal
LEDT: The external editing lock signal. When the signal is 1, the program can be edited, and it is
same as the function of the program switch on the system.
LSYS: The external operation panel lock signal. When the signal is 1, the overall operation keys on
the machine are locked.
Signal address
Parameter diagnosis (Input state at the side of the system)
State
add.
X3.1
X3.0
Pin No.
XS41.21 XS41.8
X3.0= External editing lock; X3.1= External operation panel lock.
System parameter number
0
5
9
LEDT
LOPT
LOPT
=1: Use the external operation panel lock.
=0: Do not use the external operation panel lock.
LEDT
=1:Use the external editing lock.
=0: Do not use the external editing lock.
4.13 Cooling, Lubrication and Chip-Removal Control
z
Relative M code
M08: Coolant ON
M09: Coolant OFF
M35: Chip-removal function ON
M36: Chip-removal function OFF
z
Signal
diagnosis
Parameter diagnosis (Output state at the machine side)
State
add.
Y0.1
Pin No.
XS43.14
Y0.1= Cooling switch control.
Parameter diagnosis (Output state at the machine side)
LSYS
LEDT
G016
#