Fault reason: The alarm occurs or press the “Reset” button when executing the M06 code and tool
magazine is being rotated, and therefore this alarm will be then generated.
Troubleshooting: 1. Tool magazine returns zero again.
2. Reset the tool numbers of the spindle and tool magazine.
(Refer to the details operation: Section Three The Usage and Maintenance of the GSK218MC
Series with Cone Tool-magazine)
Alarm information: 1219 Fail to rotate the spindle for the tool magazine infeed position (A002.3)
Fault reason: Tool does not the retraction in-position, perform the operation of the spindle rotation.
Troubleshooting: Return to the tool magazine to the retraction position (The X5.2 state can be
detected and check whether the tool magazine is on the retraction position).
Alarm information: 1220 Abnormal spindle tool clamping detection (A002.4)
Fault reason: Tool magazine clamping detection switch (X2.6) does not close within the setting time
of the T010 when executing the tool clamping motion (that is: Y0.2=0).
Troubleshooting: 1. Check whether the tool magazine clamping switch is normal.
2. Check whether the Y0.2 is output.
3. Readjust the time of the T010
Alarm information: 1221 Abnormal spindle tool releasing detection
Fault reason: Tool magazine releasing detection switch (X2.5) does not close within the setting time
of the T009 when performing the tool releasing motion (that is: Y0.2=1).
Troubleshooting: 1. Check whether the tool releasing detection switch is normal
2. Check whether the Y0.2 is output
3. Readjust the time of the T009
Alarm information: 1222 Abnormal spindle unit temperature detection (A002.6)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1223 Spindle velocity detection abnormality (A002.7)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1224 Abnormal spindle motor enabling detection (A003.0)
Fault reason: User self-defined
Troubleshooting: Without