Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
259
Appendix
Alarm information: 1230 Fail to perform the tool-change when spindle tool is on the releasing state.
(A003.6)
Fault reason: M06 or M50 code is performed when spindle tool is on the releasing state (Y0.2=1).
Troubleshooting: Put the spindle tool is on the clamping state (Y0.2=0)
Alarm information: 1231 Fail to perform the tool-change when the tool magazine does not at the
retraction position (A003.7).
Fault reason: M06 or M50 is performed when tool magazine is not at the retraction position.
Troubleshooting: Put the tool magazine is on the retraction position
Alarm information: 1232 Abnormal tool magazine rotation in-position detection (A004.0)
Fault reason: User self-defined
Troubleshooting:
Alarm information: Abnormal tool magazine rotation motor detection (A004.1)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1234 Program stops operation at the tool magazine infeed position (A004.2)
Fault reason: The alarm occurs when tool magazine does not at the retraction position when the
program is being operated.
Troubleshooting: Put the tool magazine at the retraction position and then perform the program
again.
Alarm information: 1235 Abnormal tool magazine movement in-position detection ( A004.3)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1236 Abnormal tool magazine zero return detection (A004.4)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1237 Tool magazine origin position lost, return to zero again (A004.5)
Fault reason: This alarm occurs when the zero return abnormality stop when the tool magazine is
performed the zero return.
Troubleshooting: Tool magazine returns to the zero position again.
(Refer to the details operation: Section Three The Usage and Maintenance of the GSK218MC
Series with Cone Tool-magazine)