Chapter Two Connection Between Equipments
175
V
o
lume IV
In
st
all
at
io
n
&
Co
nn
ect
io
n
V
o
lume IV
In
st
all
at
io
n
&
Co
nn
ect
io
n
V
o
lume IV
Inst
allation
&
C
onnecti
on
2.2.3 Signal Explanation
1. The pulse movement code signals
XCP+, XCP-, YCP+, YCP-, ZCP+, ZCP-, 4CP+ and 4CP- are code pulse signals, XDIR+, XDIR-,
YDIR+, YDIR-, ZDIR+, ZDIR-, 4DIR+ and 4DIR- are movement direction signal, and the signals of
two groups are difference output.
The circuit diagram is shown as below:
Fig. 2-2-3-1
2. The drive unit alarm signal ALM (input)
The receive method of this signal at the system side is shown below. Whether the high level or
the low is valid can be set by the bit parameter #19 (The high or the low level should comply with the
drive unit.)
+24V
DALM
R=4.7K
Fig. 2-2-3-2
3. Ready signal EN of CNC system (contact output)
Fig. 2-2-3-3