Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix II Laddar Diagram Use Guide of GSK218mc Series Matching with Disc Tool Magazine
311
Appendix
22 XS41
X003.3
Manipulator
tool-hold detection signal
NORM or NC
24 XS41
X003.4 Manipulator
zero
detection signal
NORM or NC
21
XS42
X005.1
Tool case vertical detection
NORM or NC
9
XS42
X005.2
Tool case horizontal detection
NORM or NC
22 XS42
X005.3
Tool
magazine counting (Constant 0) NORM
contactor
12
XS42
X005.5
Tool magazine zero return in-position
detection
Optional
21 XS23
X007.1 Spindle
orientation in-position
NORM or NC
2) Output section
Pin
position
Signal
interface
Mark
Pin function explanation
2 XS43
Y000.2
Tool
releasing/clamping
5 XS44
Y002.5
Manipulator operation
8 XS44
Y003.0
Tool
magazine positive
21
XS44
Y003.1
Tool magazine negative
9
XS44
Y003.2
Tool case vertical
22
XS44
Y003.3
Tool case horizontal
11 XS23
Y006.3
Spindle
orientation
C. The selection of the tool magazine switch type
Add.
Definition
Sate 0
State 1
K010.1
Whether the tool magazine is with the zero return switch
Without
With
K010.2
Whether the tool magazine zero return switch is selected the
NC type
NORM NC
K010.3
Whether the tool magazine infeed switch is selected the NC
type
NORM NC
K010.4
Whether the tool magazine retraction switch is selected the NC
type
NORM NC
K010.5
Whether the tool magazine counting switch is selected the NC
type
NORM NC
For example:
There is no zero return switch on a disk tool magazine, and each detection
switch is NORM, its parameter should be set as:
K010.1=0 K010.2=0 K010.3=0 K010.4=0 K010.5=0
D. The setting of the tool magazine capacity
Input the tool magazine capacity in the DATA100 and CTR100.
Precautions:
1. Tool magazine capacity is the tool case numbers in the tool magazine.