Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
130
V
o
lume
III Function
For example:
M5 is corresponding to the 00000101
M encoding signal
DM00 (F009
#
7)
DM01 (F009
#
6)
DM02 (F009
#
5)
DM30 (F009
#
4)
[Type]
Signal output
[Function]
These signals are shown that the miscellaneous function has been
specified actually. The corresponding table between miscellaneous
function and output signal in the program code are shown below:
Table 7-3-2
Program code
Signal output
M00 DM00
M01 DM01
M02 DM02
M30 DM30
[Output condition]
The M encoding signal is set to 1 when the following conditions are
described.
z
Specify the corresponding miscellaneous function, and any specified move
command and dwell code is completed at the same block. However, when
the end signal of the miscellaneous function returns before the move code
and dwell code, these signals are then not outputted.
The M encoding signal bit is 0 when the following conditions are performed:
z
FIN signal bit is 1.
z
When it is reset.
The end signal of M code miscellaneous function
MFIN<G000#1>
Response signal of M code miscellaneous function
MRESP<G063#0>
[Type]
Signal input
[Function]
It means that the M code miscellaneous function is completed.
[Motion]
Refer to the “M code miscellaneous function in Section 7.1” for the treatment and
process in the control unit.
The strobe signal of S code miscellaneous function
TF
(
F007
#
2
)
[Type]
Signal output
[Function]
These signals are shown that the spindle speed function has been specified