GSK218MC Series Machining Center CNC System PLC & Installation Connection Manual
68
Volume II
Operatio
n
Fig.
1-2-4-1
The content and operation of the
PLCDGN
interface:
RUN:
Operation state of the ladder diagram
ADDR:
Address of diagnosis number
Bit0~Bit7:
The bit number state of the diagnosis address. 1: with signal breakover; 0: without the
signal breakover.
Input:
Display the input data.
MDI:
Current working method
The searching and positioning can be performed by the page-up, page-down and other
direction keys, the corresponding diagnosis number then can be viewed and modified.
Generally, only the searching operation can be performed in the interface, the I/O terminal of
the PLC enters signal debugging mode, after only the user gain the limit setting that K0.1 is set to 1,
in this case, user can modify the X and Y signals.
1.2.5 PLCTRAE Interface
PLCTRA interface composes of two sub-interface “Setting” and “Trace”. Enter the PLCTRAE
“Setting” interface by pressing the [
PLCTRAE
] soft key under the screen.
Refer to the
Fig. 1-2-5-1
for PLCTRACE “Setting” interface: