55
GF 9950-10 Six Channel Transmitter
Timer - Weekday
RELAY Menu
(ALL) Select source for each Relay 1 - 4 (relay base unit) or RELAY A, B, C and D (external 8059 relay
module). Choose PRIMARY (CH 1-6), SECONDARY (CH 1-6), BINARY 1 - 4, DERIVED FUNCTION 1 - 4,
TIMER, or MULTIPLE. Secondary Values are only available for pH, Conductivity/Resistivity, Level, Salinity and
Dissolved Oxygen. Derived Functions are only available when Derived Functions (CH 1-4) are enabled in the
OPTIONS menu.
(ALL) Select the desired mode of operation to switch the Relay state (ON / OFF). Modes avaliable OFF, LOW,
HIGH, WINDow IN, WINDow OUT, PROP PULSE, VOL PULSE, PWM, TOTAL, USP and ERROR. (Refer to
page 18, Relay Modes). Default = OFF. When MODE is set to ERROR, relay energizes if sensor problem is
detected on any channel. ON DELAY delays the energizing of the relay until after the programmed delay time.
(TIMER) Allows the relay to be enabled based off either a PERIOD of time during the day or WEEKDAY to
enable the relay based on a speci
fi
c day during the week.
TIMER in WEEKDAY mode will allow the user to select which day of the week wil be enabled in the relay.
English, French, German, and Spanish only.
A custom label can be assigned to the relay for ease of identi
fi
cation.
TIMER in WEEKDAY mode will allow the user to select a day or multiple days of the week with a START
TIME, DURATION and a HOLD feature.
Default = 10:00, 60 secs, HOLD WHILE RELAY # ACTIVE NO
Enter the START TIME of the feature.
Caution:
Verify the correct time of the day is programmed into the 9950 during setup.
Enter the duration (Time ON) of the relay in SEC (seconds).
Select YES to have the Red Backlight illuminate during relay activation.
Select NO to not have the Red Backlight activated by the relay activation.
Default backlight setting - NO
(ALL) Press
▲
or
▼
to turn relay ON or OFF for testing purposes.
Can also be used to reset or latch/unlatch the relay.
Does NOT reset the Totalizer.
RELAY 1
CH 1 PRIMARY
SOURCE
RELAY 1
OFF
MODE
Relay source display allows operator to scroll thru relay 1 -4 on base unit and A-D on the external relay module.
External relays that are located in the 8059 External Relay module are limited to the basic relay modes as shown in the chart.
RELAY 1
m
TIMER
A
SOURCE
RELAY 1
m
WEEKDAY
A
MODE
RELAY 1
MULT
START TIME
IPLE
11:30
R1 DURATION
SEC
30
RELAY 1
RELAY 1
LABEL
RELAY 1 ACTIVATE
MULT
NO
IPLE
RED BACKLIGHT
RELAY 1
OFF
TEST RELAY
9
SUN
RELAY 1
9
MON
9
TUE
9
WED
9
THU
9
FRI
9
SAT