GF 9950-10 Six Channel Transmitter
Start-Up Guide
Conductivity Module Wiring
Loop Wiring
3-9950.394-1
Single Channel Cond.
SHIELD (silver)
TEMP
(white)
ISO GND (black)
SIGNAL
(red)
Shield
Black
White
Red
ISO GND
TEMP
SHLD
SIGNAL
3-9950.394-1
Single Channel
Conductivity Module
3-9950.394-2
Dual Channel
Conductivity Module
Shield
Black
White
Red
ISO GND
TEMP
SHLD
SIGNAL
Shield
Black
White
Red
ISO GND
TEMP
SHLD
SIGNAL
PLC
or
Recorder
–
+
PLC
or
Recorder
–
+
3-9950.398-2
Dual Channel 4-20mA
Loop A
+
Loop A
-
Loop B +
Loop B -
Power
Supply
–
+
Loop B+
Loop A–
Loop B–
Loop A+
3-9950.398-2
Dual Channel
4 to 20 mA Module
3-9950.395-M
Modbus Module
(Optional) Shield
Brown
Yellow
Shield recomended in
noisy environment
RS485
RCVR
PLC
–
+
GND
D0 + RS485