92
Upgrade and Maintenance Manual
RX2520
M1
Basic software procedures
I
Procedures may differ depending on your Linux OS or the definition file
on the client system. Use the following information as reference. Ask the
system administrator to change the definition file.
Ê
After replacing a network controller or the system board, switch on and boot
the server as described in section
"Switching on the server" on page 66
.
kudzu
, the hardware configuration tool for Red Hat Linux, will launch at boot
and detect the new and / or changed hardware on your system.
I
kudzu
may not launch at boot depending on the client’s environment.
Ê
Select
Keep Configuration
and
Ignore
to complete the boot process.
Ê
Use the
vi
text editor to specify the MAC address in the
HWADDR
section of
the
ifcfg-eth<x>
file:
I
The MAC address can be found on the type label attached to the
system board or network controller.
Example:
In order to modify the definition file for network controller 1, enter the
following command:
# vi /etc/sysconfig/network-scripts/ifcfg-eth1
In
vi
, specify the new MAC address as follows:
HWADDR=xx:xx:xx:xx:xx:xx
Ê
Save and close the definition file.
Ê
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
I
If the system board or network controller offers multiple LAN ports, it is
necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
Ê
Update the NIC configuration file to reflect the new card sequence and MAC
address.
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...