102
Upgrade and Maintenance Manual
RX2520
M1
Power supply units
6.1.1
Power supply unit configurations
Figure 14: Hot-plug power supply units: 450 W AC (1), 800 W AC (2), 800 W-Titanium AC (3)
I
All different hot-plug power supply units are to install, to remove or to
replace in the same way.
6.1.2
Assembly rules
– Mixed assembly of different types of hot-plug power supply units is not
supported.
– Always install a dummy cover into an unused power supply unit bay to
comply with applicable EMC regulations and satisfy cooling requirements.
– For a redundant power supply you need two hot-plug power supply units.
I
Note for servers using CMA (Cable Management Arm)
Regarding of removing power supply units, additional tasks are needed,
due to an interference between CMA stopper and the power supply units.
Ê
Unlock the CMA stopper.
Ê
Remove the CMA stopper with the mounted crossbar.
Ê
Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê
Remove the power supply unit and install a dummy cover into the
empty bay.
Ê
Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...