54
Upgrade and Maintenance Manual
RX2520
M1
Basic hardware procedures
Figure 3: Extending the server out of the rack
Ê
Remove all remaining external cables from the rear connector panel and
expansion cards (see section
"Connectors and indicators" on page 415
).
Ê
If you are not using a cable mounting arm (CMA kit), ensure that the rear
cables are long enough not to be strained or damaged when extending the
server out of the rack.
Ê
Fold down the two quick release levers on the rack mounting frame (1) and
pull the server out of the rack until it locks in place (2).
V
CAUTION!
Do not use the extended server as a surface on which to put things or as
a work surface, and strictly avoid leaning on or against it.