86
Upgrade and Maintenance Manual
RX2520
M1
Basic software procedures
Ê
Choose the
CPU
status tab.
Ê
Select the CPU which shows the pre-failure status.
Ê
Click on
Reset Status
.
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
Ê
Proceed as follows to reset the error counter of a specific processor:
Ê
Log in as root.
Ê
Enter the command below, followed by
[ENTER]
:
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
I
<CPU#>
parameters are "0" for CPU 1 and "1" for CPU 2.
Ê
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all processors:
Ê
Log in as root.
Ê
Enter the commands below, followed by
[ENTER]
:
1.
/etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2.
cd /etc/srvmagt
3.
rm -f cehist.bin
4.
/etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
Ê
Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...