RX2520 M1
Upgrade and Maintenance Manual
139
Hard disk drives / solid state drives
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Uility.
V
CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up your
data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide and manuals of RAID controller.
7.3.3.2
Removing a 3.5-inch HDD module
Figure 46: Removing a 3.5-inch HDD module
Ê
Pinch the green locking clips (1) and fully open the locking lever (2).
I
Thereby, the HDD module is pushed out of its drive bay by about 1 cm
and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
Ê
Pull the HDD module completely out of its bay.
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...