336
Upgrade and Maintenance Manual
RX2520
M1
System board and components
14.2.3 Installing the CMOS battery
Figure 228: Installing the CMOS battery
Ê
At a slight angle, fit the new CMOS battery into its socket as shown (1).
V
CAUTION!
Ensure to insert the CMOS battery with the positive pole (label side)
facing up as shown (see close-up).
Ê
Fold down the CMOS battery (2) until it locks in place.
Ê
Ensure that the locking spring (3) is properly engaged.
14.2.4 Concluding steps
Ê
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
Ê
"Reassembling" on page 59
Ê
"Connecting the server to the power source" on page 64