RX2520 M1
Upgrade and Maintenance Manual
131
Hard disk drives / solid state drives
V
CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide and manuals of RAID controller.
7.2.3.2
Removing a 2.5-inch HDD / SSD module
Figure 38: Disconnecting a 2.5-inch HDD / SSD module
Ê
Pinch the green locking clips (1) and fully open the locking lever (2).
I
Thereby, the HDD / SSD module is pushed out of its drive bay by
about 1 cm and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This is not necessary when removing a solid state drive.