17.3.2 Connectors and indicators on the I/O panel
17.3.2.1 I/O panel connectors
Figure 292: PRIMERGY RX2520 M1 rear
B
CSS
(Customer Self
Service)
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
flashing
CSS component failure
C
GEL
(Global Error
LED)
off
no critical event (non CSS component)
orange on
prefailure detected (non CSS
component)
orange
flashing
non CSS component failure
Possible reasons:
– sensor reports overheating
– sensor is defective
– CPU error
– software reports an error
F
Standby power yellow on
voltage ok
G
Main power
green on
voltage ok
H
iRMC
green
flashing
iRMC S4 ok
I
MBC
green on
power supply OK
K
MBC
orange on
power supply error
Indicator Status
Description
Содержание PRIMERGY RX2520 M1
Страница 36: ...36 Upgrade and Maintenance Manual RX2520 M1 Before you start ...
Страница 120: ...120 Upgrade and Maintenance Manual RX2520 M1 Power supply units ...
Страница 162: ...162 Upgrade and Maintenance Manual RX2520 M1 Hard disk drives solid state drives ...
Страница 169: ...RX2520 M1 Upgrade and Maintenance Manual 169 System fan Figure 73 Removing the fan box Ê Remove the two screws ...
Страница 220: ...220 Upgrade and Maintenance Manual RX2520 M1 Expansion cards and backup units ...
Страница 230: ...230 Upgrade and Maintenance Manual RX2520 M1 Main memory ...
Страница 283: ...RX2520 M1 Upgrade and Maintenance Manual 283 Accessible drives Ê Enabling BitLocker functionality on page 93 ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M1 Accessible drives ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M1 Cables ...